The network gateway ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to sub bus 2.
When the network gateway ECU receives a response signal from the ECUs connected to sub bus 2, the network gateway ECU recognizes and memorizes that the ECU is connected to sub bus 2. Based on this memorized data, the network gateway ECU monitors for malfunctions in the ECUs connected to sub bus 2 when communicating with those ECUs. If the network gateway ECU cannot receive response signals from the ECUs that have been memorized as those connected to sub bus 2, the network gateway ECU determines that a malfunction exists.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| U1002 | Lost Communication with Gateway Module (Network Gateway ECU) | The network gateway ECU cannot receive signals from all ECUs that have been memorized as those connected to sub bus 2. | ·
Open or short in sub bus 2 main line or connector ·
Open or short in sub bus 2 branch line or connector ·
Network gateway ECU ·
Driving support ECU assembly (w/ Pre-crash safety system) ·
Lane departure warning camera (w/ Lane departure alert system) ·
Television camera assembly (w/ Parking assist monitor system) ·
Blind spot monitor sensor LH (w/ Blind spot monitor system) ·
Open or short in No. 1 CAN junction connector ·
Open or short in No. 2 CAN junction connector ·
Open or short in CAN junction terminal |
|
This diagnosis procedure is for when DTC U1002 is output by the network gateway ECU (GTS display: Gateway).
Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the ignition switch to ON and wait at least 52 seconds, and then drive the vehicle at a speed of 50 km/h (31 mph) or more for 7 seconds or more.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
Check vehicle type.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Disconnect the cable from the negative (-) battery terminal.
| *a | Component with harness connected
(Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω | Below 54 Ω: Short circuit between bus lines |
| 70 Ω or higher: Open circuit in a main bus line | |||
| F85-13 (CA2H) - F85-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| F85-12 (CA2L) - F85-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| F85-13 (CA2H) - F85-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| F85-12 (CA2L) - F85-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| Open circuit in CAN main bus line | B |
| Short circuit between bus lines | C |
·
Ground short ·
+B short |
D |
A
B
C
D
Reconnect the cable to the negative (-) battery terminal.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs.
Turn the ignition switch off.
Turn the ignition switch to ON.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC U1002 is not output | A |
| DTC U1002 is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the F85 network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F85 network gateway ECU connector.
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Disconnect the M42 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-3 (CANH) - M42-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M42 CAN junction terminal connector.
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to No. 2 CAN Junction Connector |
| *c | to Network Gateway ECU |
Disconnect the F104 and F105 wire harness connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Connected to |
|---|---|---|---|
| F104-1 (CANH) - F104-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | No. 2 CAN junction connector |
| F105-1 (CANH) - F105-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | Network gateway ECU |
| Code | Color (CANH Side) | Color (CANL Side) | Connected to |
|---|---|---|---|
| F104 | BR | W | No. 2 CAN junction connector |
| F105 | L | W | Network gateway ECU |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Network gateway ECU main line) | B |
| NG (No. 2 CAN junction connector main line) | C |
A
B
C
Reconnect the F104 and F105 wire harness connectors.
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to No. 1 CAN Junction Connector |
| *c | to CAN Junction Terminal |
Disconnect the M38 and M41 wire harness connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Connected to |
|---|---|---|---|
| M38-1 (CANH) - M38-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | No. 1 CAN junction connector |
| M41-1 (CANH) - M41-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | CAN junction terminal |
| Code | Color (CANH Side) | Color (CANL Side) | Connected to |
|---|---|---|---|
| M38 | BR | W | No. 1 CAN junction connector |
| M41 | B | W | CAN junction terminal |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (No. 1 CAN junction connector main line) | B |
| NG (CAN junction terminal main line) | C |
A
B
C
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to Network Gateway ECU |
Disconnect the F105 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F105-1 (CANH) - F105-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F105 wire harness connector.
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to Network Gateway ECU |
Connect the probes of an ohmmeter to terminals 1 (CANH) and 2(CANL) of the network gateway ECU main line harness connector.
While observing the resistance value shown on the tester, disconnect the F108, M39 and M40 connectors from the No. 1 CAN junction connector or No. 2 CAN junction connector one by one until the resistance becomes normal (between 54 and 69 Ω).
| *A | w/ Lane Departure Alert System | *B | w/ Parking Assist Monitor System |
| *C | w/ Blind Spot Monitor System | - | - |
| *1 | Network Gateway ECU | *2 | Lane Departure Warning Camera |
| *3 | Television Camera Assembly | *4 | Blind Spot Monitor Sensor LH |
| *5 | CAN Junction Terminal | *6 | No. 1 CAN Junction Connector |
| *7 | No. 2 CAN Junction Connector | - | - |
| *a | Component without harness connected
(No. 1 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 2 CAN junction connector | F104 | BR | W |
| Network gateway ECU | F105 | L | W |
| Lane departure warning camera* | F108 | R | W |
*: w/ Lane Departure Alert System
| *a | Component without harness connected
(No. 2 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 1 CAN junction connector | M38 | BR | W |
| Television camera assembly*1 | M39 | B | W |
| Blind spot monitor sensor LH*2 | M40 | GR | W |
| CAN junction terminal | M41 | B | W |
*1: w/ Parking Assist Monitor System
*2: w/ Blind Spot Monitor System
Do not reconnect the disconnected connectors until this inspection is complete because there may be a short in 2 or more branch lines.
| Result | Proceed to |
|---|---|
| The resistance is still below 54 Ω when all the specified connectors are disconnected. (There are no shorts between a pair of branch lines.) | A |
| The resistance becomes normal (between 54 and 69 Ω) when a connector is disconnected. (There is a short between one or more pairs of branch lines.) | B |
When there is a short in one or more of the branch lines:
Reconnect all of the connectors to the CAN junction connector, except for the one that was disconnected last (the short-circuited bus line). Check that the resistance shown on the tester is normal (between 54 and 69 Ω) to confirm that there is a short in the one branch line only.
Connectors that connect to the CAN junction connector can be distinguished by the color of their CAN bus lines.
Reconnecting the connectors to non-original positions on the CAN junction connector does not affect system performance. However, it is preferred to reconnect the connectors to their original positions to avoid negative effects on the wiring such as tension on the wiring harnesses, and to make future maintenance easier.
A
B
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Disconnect the M41 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-1 (CANH) - M41-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to No. 2 CAN Junction Connector |
Disconnect the F104 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F104-1 (CANH) - F104-2 (CANL) | Cable disconnected from negative (-) battery terminal | 1 MΩ or higher |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to No. 1 CAN Junction Connector |
Disconnect the M38 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M38-1 (CANH) - M38-2 (CANL) | Cable disconnected from negative (-) battery terminal | 1 MΩ or higher |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Disconnect the M42 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-3 (CANH) - M42-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
| *a | Component with harness connected
(Network Gateway ECU) |
Disconnect the connector that includes terminals CANH and CANL from the ECU or sensor to which the short-circuited branch line is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω |
If the resistance becomes normal (between 54 and 69 Ω) when the connector is disconnected from the ECU or sensor, there may be a short in the ECU or sensor.
If the resistance does not become normal (between 54 and 69 Ω) when the connector is disconnected from the ECU or sensor, repair or replace the short-circuited branch line or connector.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F105 wire harness connector.
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the F85 network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Disconnect the M41 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
Connect the probes of an ohmmeter to terminals 1 (CANH) and 2 (CANL) of the M41 wire harness connector and CG or BAT of the DLC3.
It is only necessary to perform the inspection for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
While observing the resistance value shown on the ohmmeter, disconnect the F105, F108, M39 and M40 connectors from the No. 1 CAN junction connector and No. 2 CAN junction connector until the resistance becomes normal (6 kΩ or higher (for +B short) or 200 Ω or higher (for ground short)).
| *A | w/ Lane Departure Alert System | *B | w/ Parking Assist Monitor System |
| *C | w/ Blind Spot Monitor System | - | - |
| *1 | Network Gateway ECU | *2 | Lane Departure Warning Camera |
| *3 | Television Camera Assembly | *4 | Blind Spot Monitor Sensor LH |
| *5 | CAN Junction Terminal | *6 | No. 1 CAN Junction Connector |
| *7 | No. 2 CAN Junction Connector | - | - |
| *a | Component without harness connected
(No. 1 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 2 CAN junction connector | F104 | BR | W |
| Network gateway ECU | F105 | L | W |
| Lane departure warning camera* | F108 | R | W |
*: w/ Lane Departure Alert System
| *a | Component without harness connected
(No. 2 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 1 CAN junction connector | M38 | BR | W |
| Television camera assembly*1 | M39 | B | W |
| Blind spot monitor sensor LH*2 | M40 | GR | W |
| CAN junction terminal | M41 | B | W |
*1: w/ Parking Assist Monitor System
*2: w/ Blind Spot Monitor System
| Result | Proceed to |
|---|---|
| The resistance between terminals CANH and BAT, or the resistance between terminals CANL and BAT is still below 6 kΩ when all the specified connectors are disconnected from the CAN junction connector.
(There is a short to +B in the CAN main bus lines between the No. 1 CAN junction connector and No. 2 CAN junction connector.) |
A |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND is still below 200 Ω when all the specified connectors are disconnected from the CAN junction connector.
(There is a short to GND in the CAN main bus lines between the No. 1 CAN junction connector and No. 2 CAN junction connector.) |
|
| The resistance between terminals CANH and BAT, or the resistance between terminals CANL and BAT becomes normal (6 kΩ or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to +B in one of the areas that relate to one or more of the disconnected bus lines.) |
B |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND becomes normal (200 Ω or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to GND in one of the areas that relate to the disconnected bus lines.) |
A
B
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
Disconnect the M38 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M38 wire harness connector.
Disconnect the F104 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU or sensor to which the bus line shorted to +B or shorted to GND is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
If the resistance becomes normal when the connector is disconnected from the ECU, there may be a short in the ECU.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
Disconnect the M42 CAN junction terminal connector.
| *1 | DLC3 |
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M42-3 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M42-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M42-3 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M42-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Disconnect the cable from the negative (-) battery terminal.
| *a | Component with harness connected
(Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω | Below 54 Ω: Short circuit between bus lines |
| 70 Ω or higher: Open circuit in a main bus line | |||
| F85-13 (CA2H) - F85-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| F85-12 (CA2L) - F85-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| F85-13 (CA2H) - F85-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| F85-12 (CA2L) - F85-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| Open circuit in CAN main bus line | B |
| Short circuit between bus lines | C |
·
Ground short ·
+B short |
D |
A
B
C
D
Reconnect the cable to the negative (-) battery terminal.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs.
Turn the ignition switch off.
Turn the ignition switch to ON.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC U1002 is not output | A |
| DTC U1002 is output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the F85 network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F85 network gateway ECU connector.
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Disconnect the M42 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-3 (CANH) - M42-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M42 CAN junction terminal connector.
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to No. 2 CAN Junction Connector |
| *c | to Network Gateway ECU |
Disconnect the F104 and F105 wire harness connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Connected to |
|---|---|---|---|
| F104-1 (CANH) - F104-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | No. 2 CAN junction connector |
| F105-1 (CANH) - F105-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | Network gateway ECU |
| Code | Color (CANH Side) | Color (CANL Side) | Connected to |
|---|---|---|---|
| F104 | BR | W | No. 2 CAN junction connector |
| F105 | L | W | Network gateway ECU |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Network gateway ECU main line) | B |
| NG (No. 2 CAN junction connector main line) | C |
A
B
C
Reconnect the F104 and F105 wire harness connectors.
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to No. 1 CAN Junction Connector |
| *c | to CAN Junction Terminal |
Disconnect the M38 and M41 wire harness connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Connected to |
|---|---|---|---|
| M38-1 (CANH) - M38-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | No. 1 CAN junction connector |
| M41-1 (CANH) - M41-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω | CAN junction terminal |
| Code | Color (CANH Side) | Color (CANL Side) | Connected to |
|---|---|---|---|
| M38 | BR | W | No. 1 CAN junction connector |
| M41 | B | W | CAN junction terminal |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (No. 1 CAN junction connector main line) | B |
| NG (CAN junction terminal main line) | C |
A
B
C
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to Network Gateway ECU |
Disconnect the F105 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F105-1 (CANH) - F105-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F105 wire harness connector.
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to Network Gateway ECU |
Connect the probes of an ohmmeter to terminals 1 (CANH) and 2(CANL) of the network gateway ECU main line harness connector.
While observing the resistance value shown on the tester, disconnect the F108, F110, M39 and M40 connectors from the No. 1 CAN junction connector or No. 2 CAN junction connector one by one until the resistance becomes normal (between 54 and 69 Ω).
| *A | w/ Pre-crash Safety System | *B | w/ Lane Departure Alert System |
| *C | w/ Parking Assist Monitor System | *D | w/ Blind Spot Monitor System |
| *1 | Network Gateway ECU | *2 | Driving Support ECU Assembly |
| *3 | Lane Departure Warning Camera | *4 | Television Camera Assembly |
| *5 | Blind Spot Monitor Sensor LH | *6 | CAN Junction Terminal |
| *7 | No. 1 CAN Junction Connector | *8 | No. 2 CAN Junction Connector |
| *a | Component without harness connected
(No. 1 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 2 CAN junction connector | F104 | BR | W |
| Network gateway ECU | F105 | L | W |
| Lane departure warning camera*1 | F108 | R | W |
| Driving support ECU assembly*2 | F110 | G | W |
*1: w/ Lane Departure Alert System
*2: w/ Pre-crash Safety System
| *a | Component without harness connected
(No. 2 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 1 CAN junction connector | M38 | BR | W |
| Television camera assembly*1 | M39 | B | W |
| Blind spot monitor sensor LH*2 | M40 | GR | W |
| CAN junction terminal | M41 | B | W |
*1: w/ Parking Assist Monitor System
*2: w/ Blind Spot Monitor System
Do not reconnect the disconnected connectors until this inspection is complete because there may be a short in 2 or more branch lines.
| Result | Proceed to |
|---|---|
| The resistance is still below 54 Ω when all the specified connectors are disconnected. (There are no shorts between a pair of branch lines.) | A |
| The resistance becomes normal (between 54 and 69 Ω) when a connector is disconnected. (There is a short between one or more pairs of branch lines.) | B |
When there is a short in one or more of the branch lines:
Reconnect all of the connectors to the CAN junction connector, except for the one that was disconnected last (the short-circuited bus line). Check that the resistance shown on the tester is normal (between 54 and 69 Ω) to confirm that there is a short in the one branch line only.
Connectors that connect to the CAN junction connector can be distinguished by the color of their CAN bus lines.
Reconnecting the connectors to non-original positions on the CAN junction connector does not affect system performance. However, it is preferred to reconnect the connectors to their original positions to avoid negative effects on the wiring such as tension on the wiring harnesses, and to make future maintenance easier.
A
B
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Disconnect the M41 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-1 (CANH) - M41-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to No. 1 CAN Junction Connector) |
| *b | to No. 2 CAN Junction Connector |
Disconnect the F104 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F104-1 (CANH) - F104-2 (CANL) | Cable disconnected from negative (-) battery terminal | 1 MΩ or higher |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to No. 1 CAN Junction Connector |
Disconnect the M38 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M38-1 (CANH) - M38-2 (CANL) | Cable disconnected from negative (-) battery terminal | 1 MΩ or higher |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Disconnect the M42 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M42-3 (CANH) - M42-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
| *a | Component with harness connected
(Network Gateway ECU) |
Disconnect the connector that includes terminals CANH and CANL from the ECU or sensor to which the short-circuited branch line is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω |
If the resistance becomes normal (between 54 and 69 Ω) when the connector is disconnected from the ECU or sensor, there may be a short in the ECU or sensor.
If the resistance does not become normal (between 54 and 69 Ω) when the connector is disconnected from the ECU or sensor, repair or replace the short-circuited branch line or connector.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the F105 wire harness connector.
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the F85 network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F85-13 (CA2H) - F85-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Disconnect the M41 wire harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
Connect the probes of an ohmmeter to terminals 1 (CANH) and 2 (CANL) of the J603 wire harness connector and CG or BAT of the DLC3.
It is only necessary to perform the inspection for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
While observing the resistance value shown on the ohmmeter, disconnect the F105, F108, F110, M39 and M40 connectors from the No. 1 CAN junction connector and No. 2 CAN junction connector until the resistance becomes normal (6 kΩ or higher (for +B short) or 200 Ω or higher (for ground short)).
| *A | w/ Pre-crash Safety System | *B | w/ Lane Departure Alert System |
| *C | w/ Parking Assist Monitor System | *D | w/ Blind Spot Monitor System |
| *1 | Network Gateway ECU | *2 | Driving Support ECU Assembly |
| *3 | Lane Departure Warning Camera | *4 | Lane Departure Warning Camera |
| *5 | Blind Spot Monitor Sensor LH | *6 | CAN Junction Terminal |
| *7 | No. 1 CAN Junction Connector | *8 | No. 2 CAN Junction Connector |
| *a | Component without harness connected
(No. 1 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 2 CAN junction connector | F104 | BR | W |
| Network gateway ECU | F105 | L | W |
| Lane departure warning camera*1 | F108 | R | W |
| Driving support ECU assembly*2 | F110 | G | W |
*1: w/ Lane Departure Alert System
*2: w/ Pre-crash Safety System
| *a | Component without harness connected
(No. 2 CAN Junction Connector) |
- | - |
| No. 1 CAN Junction Connector Side | Code | Color (CANH Side) | Color (CANL Side) |
|---|---|---|---|
| No. 1 CAN junction connector | M38 | BR | W |
| Television camera assembly*1 | M39 | B | W |
| Blind spot monitor sensor LH*2 | M40 | GR | W |
| CAN junction terminal | M41 | B | W |
*1: w/ Parking Assist Monitor System
*2: w/ Blind Spot Monitor System
| Result | Proceed to |
|---|---|
| The resistance between terminals CANH and BAT, or the resistance between terminals CANL and BAT is still below 6 kΩ when all the specified connectors are disconnected from the CAN junction connector.
(There is a short to +B in the CAN main bus lines between the No. 1 CAN junction connector and No. 2 CAN junction connector.) |
A |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND is still below 200 Ω when all the specified connectors are disconnected from the CAN junction connector.
(There is a short to GND in the CAN main bus lines between the No. 1 CAN junction connector and No. 2 CAN junction connector.) |
|
| The resistance between terminals CANH and BAT, or the resistance between terminals CANL and BAT becomes normal (6 kΩ or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to +B in one of the areas that relate to one or more of the disconnected bus lines.) |
B |
| The resistance between terminals CANH and GND, or the resistance between terminals CANL and GND becomes normal (200 Ω or higher) when a connector is disconnected from the CAN junction connector.
(There is a short to GND in one of the areas that relate to the disconnected bus lines.) |
A
B
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
Disconnect the M38 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M38 wire harness connector.
Disconnect the F104 wire harness connector.
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
| *b | to CAN Junction Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
Before disconnecting the connectors, make a note of where they are connected.
Reconnect each connector to its original position.
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (No. 1 CAN junction connector and No. 2 CAN junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU or sensor to which the bus line shorted to +B or shorted to GND is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
| *1 | DLC3 |
| *a | Rear view of wire harness connector
(to No. 2 CAN Junction Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M41-1 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M41-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M41-1 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M41-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
If the resistance becomes normal when the connector is disconnected from the ECU, there may be a short in the ECU.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the M41 wire harness connector.
Disconnect the M42 CAN junction terminal connector.
| *1 | DLC3 |
| *a | Front view of wire harness connector
(to CAN Junction Terminal) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| M42-3 (CANH) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| M42-2 (CANL) - F25-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| M42-3 (CANH) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| M42-2 (CANL) - F25-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG