Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)
RM3160E _59 Vehicle Exterior _019717 WINDOW / GLASS _0106113 POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows) J

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)  Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated)  


DESCRIPTION

If a door glass or a power window regulator motor assembly does not operate smoothly, the jam protection function may be triggered automatically, resulting in the auto up operation being unable to fully close the window.

CAUTION / NOTICE / HINT

NOTICE:
·

If a power window regulator motor assembly has been replaced with a new one, initialize the power window control system.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION

·

If a power window regulator motor assembly and door window regulator sub-assembly have been removed and installed, or if a power window regulator motor assembly was reused when a door glass or door glass run was replaced, initialize the power window control system.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION



HINT:

This symptom may occur for any of the windows.


PROCEDURE

1.PERFORM INITIALIZATION (APPLICABLE LOCATION)
a.

Initialize the power window regulator motor assembly (applicable location).

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>INITIALIZATION


Result:
Proceed to
NEXT



NEXT

2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION (APPLICABLE LOCATION))
2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION (APPLICABLE LOCATION))
a.

Check that each power window moves when the auto up and down function of the power window regulator master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly is operated.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(for Models with Jam Protection Function on 4 Windows)>OPERATION CHECK

OK:

Auto up and down function is normal (applicable location).



Result:
Proceed to
OK
NG



OK

END (PROBLEM DUE TO INITIALIZATION FAILURE)

NG

3.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)
3.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION)
a.

Remove the window regulator.


b.

Install the window glass to the door glass run.


c.

Check if the door window regulator operates smoothly.


d.

Check that the window glass slides smoothly when sliding it up by hand.

CAUTION:

Perform initialization again.


HINT:
Ensure the following:
·

The window glass fits in the glass run without improper contact or deformation.

·

Foreign matter is not caught in the glass run.



OK:

Door window glass slides smoothly.



Result:
Result Proceed to
OK (Driver door power window) A
OK (Front passenger door power window)
OK (Rear LH door power window) B
OK (Rear RH door power window)
NG C



A

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR DRIVER DOOR OR FRONT PASSENGER DOOR)

B

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR REAR LH DOOR OR REAR RH DOOR)

C

FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN MATTER CAUSING IMPROPER FIT OR REPLACE PARTS)