Home › Engine / Hybrid System › 1AR-FE STARTING › STARTER › from 2016.11
RM3160E _51 Engine / Hybrid System _019678 1AR-FE STARTING _0105667 STARTER A

1AR-FE STARTING  STARTER  INSTALLATION  


PROCEDURE

Hide 28100 1.INSTALL STARTER ASSEMBLY

a.

Type B:

i.
A386434C03
1.583,3.427 1.896,3.583 0.313,0.156 10 false *a 1.583,3.927 1.896,4.083 0.313,0.156 10 false *b 2.771,3.667 3.083,3.823 0.313,0.156 10 false *c
*a 26.5 mm (1.043 in.)
*b 18 mm (0.709 in.)
*c 50 mm (1.969 in.)


Using an E8 "TORX" socket wrench, install the 2 stud bolts to the automatic transaxle assembly.

Torque:
37 N*m (377 kgf*cm, 27 ft.*lbf)


ii.

Install the starter assembly with the 2 bolts.

Torque:
37 N*m (377 kgf*cm, 27 ft.*lbf)



b.

Type A:

i.

Install the starter assembly with the 2 bolts.

Torque:
37 N*m (377 kgf*cm, 27 ft.*lbf)



c.

Connect the starter assembly connector.


d.

Connect terminal 30 with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


e.

Close the terminal cap.


Hide 17701 3.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

Hide 17801 4.INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 17705 5.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

Hide 17750A 6.INSTALL INLET AIR CLEANER ASSEMBLY

Hide 12601B 7.INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

Hide 53295E 8.INSTALL COOL AIR INTAKE DUCT SEAL

Hide 53298E 9.INSTALL RADIATOR SIDE SEAL RH

Hide 53299D 10.INSTALL RADIATOR SIDE DEFLECTOR SEAL LH

Hide 11.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION