The evaporator temp. sensor (No. 1 cooler thermistor) is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temp. sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1413 | Evaporator Temperature Circuit or Evaporator Fin Thermistor | Open or short in evaporator temperature sensor circuit | ·
Evaporator temp. sensor (No. 1 cooler thermistor) ·
Air conditioning harness assembly ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Evaporator Fin Thermistor | Evaporator temp. sensor (No. 1 cooler thermistor) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Tester Display |
|---|
| Evaporator Fin Thermistor |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the air conditioning harness assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for HV Model)>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| *a | Front view of air conditioning harness assembly connector
(to Air Conditioning Amplifier Assembly) |
*b | Front view of air conditioning harness assembly connector
(to Evaporator Temp. Sensor (No. 1 Cooler Thermistor)) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z19-6 (TE) - A-2 | Always | Below 1 Ω |
| z19-5 (SG) - A-1 | Always | Below 1 Ω |
| z19-6 (TE) or A-2 - Other terminals and body ground | Always | 10 kΩ or higher |
| z19-5 (SG) or A-1 - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for HV Model)>DISASSEMBLY