Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for HV Model)
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0420832 AIR CONDITIONING SYSTEM(for HV Model) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  B1442  Air Inlet Damper Control Servo Motor Circuit  


DESCRIPTION

The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position.

The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position to change the air inlet mode (fresh, recirculation/fresh, and recirculation).

The air conditioning amplifier assembly communicates with the servo through the communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1442 Air Inlet Damper Control Servo Motor Circuit Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
·

No. 1 blower damper servo sub-assembly

·

No. 1 air conditioning radiator damper servo sub-assembly

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly

·

Blower assembly


Memorized
(30 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition No. 1 blower damper servo sub-assembly operating ○ ○
Malfunction Air inlet damper servo operation request signals are output but the air inlet damper position sensor value does not change ○ -
Air inlet damper servo operation request signals are output but the air inlet damper position sensor value is abnormal - ○
Detection Time Continuously for 30 seconds or more Continuously for 30 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored.


WIRING DIAGRAM

E432281E04
0.375,4.563 1.698,4.979 1.323,0.417 10 false No. 1 Blower Damper Servo Sub-assembly 5.854,2.302 6.167,2.5 0.313,0.198 10 false IC 5.167,4.542 7.052,4.948 1.885,0.406 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.729,5.385 2.552,5.635 1.823,0.25 10 false : LIN Communication Line 2.563,4.594 4.083,5.021 1.521,0.427 10 false Air Conditioning Harness Assembly 0.906,1.615 2.448,1.99 1.542,0.375 10 false Air Conditioning Amplifier Assembly 1.75,0.51 2.208,0.708 0.458,0.198 10 false BUS 1.604,0.917 2.219,1.115 0.615,0.198 10 false B BUS 1.604,1.313 2.208,1.521 0.604,0.208 10 false BUS G 2.281,2.75 2.438,2.948 0.156,0.198 10 false 1 2.281,2.344 2.438,2.542 0.156,0.198 10 false 2 2.281,3.146 2.438,3.344 0.156,0.198 10 false 3 2.292,3.542 2.448,3.74 0.156,0.198 10 false 4 2.281,3.938 2.438,4.135 0.156,0.198 10 false 5 4.885,2.75 5.042,2.948 0.156,0.198 10 false 4 1.813,3.625 2.125,3.823 0.313,0.198 10 false M+ 1.813,4.021 2.125,4.219 0.313,0.198 10 false M- 1.719,2.823 2.135,3.021 0.417,0.198 10 false GND 2.271,2.542 2.427,2.74 0.156,0.198 10 false B 2.271,2.938 2.427,3.135 0.156,0.198 10 false B 2.271,3.333 2.427,3.531 0.156,0.198 10 false B 2.271,3.729 2.427,3.927 0.156,0.198 10 false B 2.271,4.125 2.427,4.323 0.156,0.198 10 false B 4.875,2.542 5.031,2.74 0.156,0.198 10 false A 4.875,2.938 5.031,3.135 0.156,0.198 10 false A 4.875,3.333 5.031,3.531 0.156,0.198 10 false A 4.875,3.729 5.031,3.927 0.156,0.198 10 false A 4.875,4.125 5.031,4.323 0.156,0.198 10 false A 5.198,3.615 5.51,3.813 0.313,0.198 10 false M+ 5.208,4 5.521,4.198 0.313,0.198 10 false M- 1.74,3.219 2.177,3.417 0.438,0.198 10 false sigB 5.198,2.438 5.635,2.635 0.438,0.198 10 false STE1 5.198,2.833 5.615,3.031 0.417,0.198 10 false GND 4.875,1.323 5.031,1.521 0.156,0.198 10 false A 4.875,0.927 5.031,1.125 0.156,0.198 10 false A 4.875,0.51 5.031,0.708 0.156,0.198 10 false A 4.896,2.344 5.052,2.542 0.156,0.198 10 false 5 4.885,3.146 5.042,3.344 0.156,0.198 10 false 6 4.885,3.531 5.042,3.729 0.156,0.198 10 false 7 4.885,3.927 5.042,4.125 0.156,0.198 10 false 8 2.198,0.521 2.531,0.76 0.333,0.24 10 false z19 2.198,0.927 2.531,1.167 0.333,0.24 10 false z19 2.198,1.313 2.531,1.552 0.333,0.24 10 false z19 2.271,0.313 2.427,0.51 0.156,0.198 10 false 3 2.271,0.729 2.427,0.927 0.156,0.198 10 false 4 2.271,1.135 2.427,1.333 0.156,0.198 10 false 2 4.885,0.323 5.042,0.521 0.156,0.198 10 false 2 4.875,0.729 5.031,0.927 0.156,0.198 10 false 1 4.885,1.125 5.042,1.323 0.156,0.198 10 false 3 5.219,0.354 5.677,0.552 0.458,0.198 10 false BUS 5.219,0.802 5.833,1 0.615,0.198 10 false B BUS 5.219,1.188 5.823,1.396 0.604,0.208 10 false BUS G 1.75,2.427 2.188,2.625 0.438,0.198 10 false sigA 5.198,3.219 5.635,3.417 0.438,0.198 10 false STE2

CAUTION / NOTICE / HINT

NOTICE:
·

Confirm that no mechanical problems are present because this DTC can be stored when either a damper link or damper is mechanically locked.

·

When installing a damper servo motor, make sure to install it correctly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY

·

After replacing a damper servo motor, make sure to perform servo motor initialization.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>INITIALIZATION



PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
DTC B1497 is not output A
DTC B1497 is output B



A

2.CHECK FOR DTC

B

2.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
DTC B1441, B1446 and B1448 are not output A
DTC B1441, B1446 or B1448 is output B



A

3.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

3.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (INSTALLATION CONDITION)
a.

Check that the No. 1 blower damper servo sub-assembly is installed correctly.

OK:

No. 1 blower damper servo sub-assembly is installed correctly.



Result:
Proceed to
OK
NG



OK

4.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)

NG

REINSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

4.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
a.

Check for a wire harness caught between the links of the motors and dampers.

OK:

No wire harnesses are caught between the links of the motors and dampers.



Result:
Proceed to
OK
NG



OK

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

REMOVE PINCHED WIRE HARNESS

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY
a.

Disconnect the No. 1 air conditioning radiator damper servo sub-assembly connector.


b.

Disconnect the No. 1 blower damper servo sub-assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-6 (STE2) - B-3 (sigB) Always Below 1 Ω
A-5 (STE1) - B-2 (sigA) Always Below 1 Ω
A-8 (M-) - B-5 (M-) Always Below 1 Ω
A-7 (M+) - B-4 (M+) Always Below 1 Ω
A-4 (GND) - B-1 (GND) Always Below 1 Ω
A-6 (STE2) or B-3 (sigB) - Other terminals and Body ground Always 10 kΩ or higher
A-5 (STE1) or B-2 (sigA) - Other terminals and Body ground Always 10 kΩ or higher
A-8 (M-) or B-5 (M-) - Other terminals and Body ground Always 10 kΩ or higher
A-7 (M+) or B-4 (M+) - Other terminals and Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.CHECK BLOWER ASSEMBLY (DAMPER)

NG

6.CHECK BLOWER ASSEMBLY (DAMPER)
a.

Remove the No. 1 blower damper servo sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY


b.

Operate the dampers by hand.

OK:

The dampers are easily operated by hand.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPAIR OR REPLACE BLOWER ASSEMBLY