Refer to DTC C050612.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C050614 | Right Front Wheel Speed Sensor Circuit Short to Ground or Open | An open in the speed sensor signal circuit continues for 0.5 seconds or more. | ·
Front speed sensor RH ·
Wire harness and connector ·
Skid control ECU (brake actuator assembly) |
Refer to DTC C050612.
After replacing the skid control ECU (brake actuator assembly), perform "Calibration".
After replacing or removing and installing a speed sensor, perform Dealer Mode (Signal Check) inspection to confirm that the speed sensors are operating correctly.
Select the line graph display on the GTS.
Check for any momentary interruption in the wire harness and connector.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FR Speed Open | Front speed sensor RH open detection | Normal / Under intermittent | Normal: Momentary interruption not detected
Under intermittent: Momentary interruption detected |
- |
| FR Speed Sensor Voltage Open | Front speed sensor RH voltage open detection | Normal / Under intermittent | Normal: Momentary interruption not detected
Under intermittent: Momentary interruption detected |
- |
| Tester Display |
|---|
| FR Speed Open |
| FR Speed Sensor Voltage Open |
Normal (There are no momentary interruptions.)
Perform the above inspection before removing the sensor and connector.
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
Turn the ignition switch off.
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
The connector is securely connected.
Disconnect the A40 front speed sensor RH connector.
Disconnect the A39 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A40-1 (FR+) - A39-7 (FR+) | Always | Below 1 Ω |
| A40-1 (FR+) or A39-7 (FR+) - Body ground | Always | 10 kΩ or higher |
| A40-2 (FR-) - A39-6 (FR-) | Always | Below 1 Ω |
| A40-2 (FR-) or A39-6 (FR-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Front Speed Sensor RH) |
Reconnect the A39 skid control ECU (brake actuator assembly) connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A40-1 (FR+) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for Gasoline Model LHD)>REMOVAL