The battery cooling blower assembly speed is controlled by the battery voltage sensor. Power is supplied to the battery cooling blower assembly when the MREL terminal of the hybrid vehicle control ECU turns on the IGCT relay. The battery voltage sensor sends command signals (SI0 and SI1) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the HV battery temperature. The frequency (FP0 and FP1) of the battery cooling blower assembly is sent to the hybrid vehicle control ECU via the battery voltage sensor as a monitor signal using CAN communication.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly (No. 0) output frequency is not within the target control speed range. ·
The battery cooling blower assembly (No. 0) speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (2 trip detection logic) |
·
Battery voltage sensor ·
Battery cooling blower assembly (No. 0) ·
BATT FAN NO. 1 fuse ·
BATT FAN NO. 1 relay ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P0A814B | Hybrid/EV Battery Cooling Fan 1 Over Temperature | Both of the following conditions are met:
·
The HV battery temperature is high and the speed calculated based on the battery cooling blower assembly (No. 0) output frequency is not within the target control speed range. ·
The HV battery temperature is high and the battery cooling blower assembly (No. 0) speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (1 trip detection logic) |
·
Battery voltage sensor ·
Battery cooling blower assembly (No. 0) ·
BATT FAN NO. 1 fuse ·
BATT FAN NO. 1 relay ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P0A9611 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Ground | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly (No. 1) output frequency is not within the target control speed range. ·
The battery cooling blower assembly (No. 1) speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (2 trip detection logic) |
·
Battery voltage sensor ·
Battery cooling blower assembly (No. 1) ·
BATT FAN NO. 2 fuse ·
BATT FAN NO. 2 relay ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P0A964B | Hybrid/EV Battery Cooling Fan 2 Over Temperature | Both of the following conditions are met:
·
The HV battery temperature is high and the speed calculated based on the battery cooling blower assembly (No. 1) output frequency is not within the target control speed range. ·
The HV battery temperature is high and the battery cooling blower assembly (No. 1) speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (1 trip detection logic) |
·
Battery voltage sensor ·
Battery cooling blower assembly (No. 1) ·
BATT FAN NO. 2 fuse ·
BATT FAN NO. 2 relay ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| DTC No. | Data List |
|---|---|
| P0A8111 | ·
Hybrid Battery Cooling Fan 1 Drive Request ·
Hybrid Battery Cooling Fan 1 Drive Status ·
Hybrid Battery Cooling Fan 1 Frequency |
| P0A814B | |
| P0A9611 | ·
Hybrid/EV Battery Cooling Fan 2 Drive Request ·
Hybrid/EV Battery Cooling Fan 2 Drive Status ·
Hybrid/EV Battery Cooling Fan 2 Frequency |
| P0A964B |
The following items can be helpful when performing repairs:
Hybrid Battery Temperature 1 to 6
BATT Voltage
"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly (No. 0) is operating and its value changes in proportion to the battery cooling blower assembly (No. 0) speed.
"Hybrid/EV Battery Cooling Fan 2 Frequency" is detected when the battery cooling blower assembly (No. 1) is operating and its value changes in proportion to the battery cooling blower assembly (No. 1) speed.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Control the Hybrid Battery Cooling Fan.
Select fan mode 1 and operate the battery cooling blower assembly and wait for 60 seconds or more.
Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
As the battery cooling blower assembly speed is excessively low, there is a possibility of an open or short to ground in connected circuits, or motor locking.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0AFC00 or P0AFC96 is not output. | A |
| P0AFC00 or P0AFC96 is output. | B |
Turn the ignition switch off.
A
B
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| P0A8111 or P0A814B is also output. | A |
| P0A9611 or P0A964B is also output. | B |
A
B
Clear the DTCs and Freeze Frame Data.
Select fan mode 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 0).
If the Active Test cannot be performed, skip it and proceed to the next step to check if the fan operates and air is sucked in. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 0).
| Tester Display |
|---|
| Control the Hybrid Battery Cooling Fan |
Check that the battery cooling blower assembly (No. 0) operates, air is sucked into the inlet duct and the operation sound is normal.
The battery cooling blower assembly (No. 0) may not stop even when turning the cooling fan off in the "Control the Hybrid Battery Cooling Fan" Active Test. This is due to HV system control and is not a malfunction.
The battery cooling blower assembly (No. 0) operates.
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-11 (FP0) - M49-2 (FP0) | Ignition switch off | Below 1 Ω |
| y1-11 (FP0) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-11 (FP0) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery voltage sensor connector and battery cooling blower assembly (No. 0).
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 0).
If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling fan assembly (No. 0).
| Active Test Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid Battery Cooling Fan 1 Frequency |
| *a | Component with harness connected
(Battery Voltage Sensor) |
While the battery cooling blower assembly (No. 0) is operating, compare the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery voltage sensor connector.
| Tester Connection | Condition |
|---|---|
| y1-11 (FP0) - y1-7 (GND) | Battery cooling blower assembly (No. 0) is operating. |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each fan mode 1 to 6. If the Active Test cannot be performed, compare the values only in the current fan mode.
| Result | Proceed to |
|---|---|
| Both of the values in the Data List (Hybrid Battery Cooling Fan 1 Frequency) and the actual measured value at the battery voltage sensor connector are 0 Hz. | A |
| Other than above | B |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M49-2 (FP0) - M49-4 (GND0) | Ignition switch ON | 4.5 to 5.5 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 0).
If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 0).
| Active Test Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid Battery Cooling Fan 1 Frequency |
| *a | Component with harness connected
(Battery Voltage Sensor) |
While the battery cooling blower assembly (No. 0) is operating, compare the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery voltage sensor connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-11 (FP0) - y1-7 (GND) | Battery cooling blower assembly (No. 0) is operating. | Difference between the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) and the actual measured value at the battery voltage sensor connector is 10% or less. |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each fan mode 1 to 6. If the Active Test cannot be performed, compare the values only in the current fan mode.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 1 Fuse |
Remove the BATT FAN NO. 1 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| BATT FAN NO. 1 fuse | Always | Below 1 Ω |
Install the BATT FAN NO. 1 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 1 Relay |
Remove the BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M49-1 (IG0) - M49-4 (GND0) | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Installation condition of fuse(s) (before removing fuse(s)) (IG circuit)
Fuse condition (before and after removing fuse(s)) (IG circuit)
Connection condition of connectors (IG circuit)
Wire harness condition (IG circuit)
Wire harness condition (GND circuit)
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check that each connector between the battery voltage sensor and battery cooling blower assembly (No. 0) is not loose or disconnected.
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check the terminals of the connector for deformation and corrosion.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-5 (SI0) - M49-3 (SI0) | Ignition switch off | Below 1 Ω |
| M49-3 (SI0) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Make sure that each connector between the battery voltage sensor and battery cooling blower assembly (No. 0) is not loose or disconnected and its terminals are not deformed or corroded.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M49-3 (SI0) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery voltage sensor connector and battery cooling blower assembly (No. 0).
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the battery voltage sensor.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY VOLTAGE SENSOR>REMOVAL
| *a | Component without harness connected
(Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-5 (SI0) - y1-7 (GND) | Ignition switch off | 10 kΩ or higher |
Install the battery voltage sensor.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-5 (SI0) - y1-7 (GND) | Ignition switch ON | 4.5 to 5.5 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 0).
If the Active Test cannot be performed, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 0).
| Tester Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| *a | Component with harness connected
(Battery Voltage Sensor) |
Connect an oscilloscope to the y1 battery voltage sensor connector and check the waveform.
| Item | Content |
|---|---|
| Tester Connection | y1-5 (SI0) - y1-7 (GND) |
| Equipment Setting | 10 V/DIV., 1 ms./DIV. |
| Condition | Ignition switch ON, during Active Test |
Perform this inspection with the battery voltage sensor connector connected.
The wave length will vary with the operating speed of the battery cooling blower assembly (No. 0).
| Result | Proceed to |
|---|---|
| Normal (The pulse output of waveform 1) | A |
| No pulse generation | B |
Turn the ignition switch off.
| *a | Waveform 1 |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M49-4 (GND0) - Body ground | Ignition switch off | Below 1 Ω |
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-7 (GND) - Body ground | Ignition switch off | Below 1 Ω |
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT NO. 2 fuse, BATT FAN NO. 1 relay and BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse Holder |
| *3 | BATT FAN NO. 1 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (IGCT NO. 2 fuse holder) - 1 (BATT FAN NO. 1 relay holder) | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the IGCT NO. 2 fuse, BATT FAN NO. 1 relay and BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 1 Relay Holder |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BATT FAN NO. 1 relay holder) - Body ground | Ignition switch off | 11 to 14 V |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 1 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BATT FAN NO. 1 relay holder) - Body ground | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Check the terminals of the relay for deformation and corrosion.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Check that each connector between the BATT FAN NO. 1 relay and battery cooling blower assembly (No. 0) is not loose or disconnected.
Before disconnecting the connector, check that it is not loose or disconnected.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | BATT FAN NO. 1 Relay Holder |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (BATT FAN NO. 1 relay holder) - M49-1 (IG0) | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Check that each connector between the BATT FAN NO. 1 relay and battery cooling blower assembly (No. 0) is not loose or disconnected.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
Install the BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 1 fuse and BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 1 Fuse Holder |
| *3 | BATT FAN NO. 1 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BATT FAN NO. 1 fuse holder) - Terminals other than 3 (BATT FAN NO. 1 relay holder) and body ground | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 1 fuse and BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the BATT FAN NO. 1 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | BATT FAN NO. 1 Relay Holder |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 0)) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (BATT FAN NO. 1 relay holder) - M49-1 (IG0) | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
Install the BATT FAN NO. 1 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M49 battery cooling blower assembly (No. 0) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Component without harness connected
(Battery Cooling Blower Assembly (No. 0)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M49-1 (IG0) - M49-4 (GND0) and Body ground | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Reconnect the M49 battery cooling blower assembly (No. 0) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Clear the DTCs and Freeze Frame Data.
Select fan mode 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 1).
If the Active Test cannot be performed, skip it and proceed to the next step to check if the fan operates and air is sucked in. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 1).
| Tester Display |
|---|
| Control the Hybrid Battery Cooling Fan |
Check that the battery cooling blower assembly (No. 1) operates, air is sucked into the inlet duct and the operation sound is normal.
The battery cooling blower assembly (No. 1) may not stop even when turning the cooling fan off in the "Control the Hybrid Battery Cooling Fan" Active Test. This is due to HV system control and is not a malfunction.
The battery cooling blower assembly (No. 1) operates.
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-12 (FP1) - M50-2 (FP1) | Ignition switch off | Below 1 Ω |
| y1-12 (FP1) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-12 (FP1) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery voltage sensor connector and battery cooling blower assembly (No. 1).
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 1).
If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling fan assembly (No. 1).
| Active Test Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid/EV Battery Cooling Fan 2 Frequency |
| *a | Component with harness connected
(Battery Voltage Sensor) |
While the battery cooling blower assembly (No. 1) is operating, compare the value in the Data List (Hybrid/EV Battery Cooling Fan 2 Frequency) with the frequency value that was actually measured at the battery voltage sensor connector.
| Tester Connection | Condition |
|---|---|
| y1-12 (FP1) - y1-7 (GND) | Battery cooling blower assembly (No. 1) is operating. |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each fan mode 1 to 6. If the Active Test cannot be performed, compare the values only in the current fan mode.
| Result | Proceed to |
|---|---|
| Both of the values in the Data List (Hybrid/EV Battery Cooling Fan 2 Frequency) and the actual measured value at the battery voltage sensor connector are 0 Hz. | A |
| Other than above | B |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M50-2 (FP1) - M50-4 (GND1) | Ignition switch ON | 4.5 to 5.5 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 1).
If the Active Test cannot be performed, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 1).
| Active Test Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid/EV Battery Cooling Fan 2 Frequency |
| *a | Component with harness connected
(Battery Voltage Sensor) |
While the battery cooling blower assembly (No. 1) is operating, compare the value in the Data List (Hybrid/EV Battery Cooling Fan 2 Frequency) with the frequency value that was actually measured at the battery voltage sensor connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-12 (FP1) - y1-7 (GND) | Battery cooling blower assembly (No. 1) is operating. | Difference between the value in the Data List (Hybrid/EV Battery Cooling Fan 2 Frequency) and the actual measured value at the battery voltage sensor connector is 10% or less. |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each fan mode 1 to 6. If the Active Test cannot be performed, compare the values only in the current fan mode.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 2 Fuse |
Remove the BATT FAN NO. 2 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance of the BATT FAN NO. 2 fuse.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| BATT FAN NO. 2 fuse | Ignition switch off | Below 1 Ω |
Install the BATT FAN NO. 2 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 2 Relay |
Remove the BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M50-1 (IG1) - M50-4 (GND1) | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Installation condition of fuse(s) (before removing fuse(s)) (IG circuit)
Fuse condition (before and after removing fuse(s)) (IG circuit)
Connection condition of connectors (IG circuit)
Wire harness condition (IG circuit)
Wire harness condition (GND circuit)
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check that each connector between the battery voltage sensor and battery cooling blower assembly (No. 1) is not loose or disconnected.
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check the terminals of the connector for deformation and corrosion.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-6 (SI1) - M50-3 (SI1) | Ignition switch off | Below 1 Ω |
| M50-3 (SI1) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Make sure that each connector between the battery voltage sensor and battery cooling blower assembly (No. 1) is not loose or disconnected and its terminals are not deformed or corroded.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M50-3 (SI1) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery voltage sensor connector and battery cooling blower assembly (No. 1).
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the battery voltage sensor.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY VOLTAGE SENSOR>REMOVAL
| *a | Component without harness connected
(Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-6 (SI1) - y1-7 (GND) | Ignition switch off | 10 kΩ or higher |
Install the battery voltage sensor.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-6 (SI1) - y1-7 (GND) | Ignition switch ON | 4.5 to 5.5 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and Freeze Frame Data.
Select each fan mode 1 to 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly (No. 1).
If the Active Test cannot be performed, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the battery voltage sensor sends a command to operate the battery cooling blower assembly (No. 1).
| Tester Display |
|---|
| Control the Hybrid Battery Cooling Fan |
| *a | Component with harness connected
(Battery Voltage Sensor) |
Connect an oscilloscope to the y1 battery voltage sensor connector and check the waveform.
| Item | Content |
|---|---|
| Tester Connection | y1-6 (SI1) - y1-7 (GND) |
| Equipment Setting | 10 V/DIV., 1 ms./DIV. |
| Condition | Ignition switch ON, during Active Test |
Perform this inspection with the battery voltage sensor connector connected.
The wave length will vary with the operating speed of the battery cooling blower assembly (No. 1).
| Result | Proceed to |
|---|---|
| Normal (The pulse output of waveform 1) | A |
| No pulse generation | B |
Turn the ignition switch off.
| *a | Waveform 1 |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the HV battery junction block assembly.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M50-4 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect the y1 battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| y1-7 (GND) - Body ground | Ignition switch off | Below 1 Ω |
Reconnect the y1 battery voltage sensor connector.
Install the HV battery junction block assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT NO. 2 fuse, BATT FAN NO. 1 relay and BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse Holder |
| *3 | BATT FAN NO. 2 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (IGCT NO. 2 fuse holder) - 1 (BATT FAN NO. 2 relay holder) | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the IGCT NO. 2 fuse, BATT FAN NO. 1 relay and BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 2 Relay Holder |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BATT FAN NO. 2 relay holder) - Body ground | Ignition switch ON | 11 to 14 V |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 2 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BATT FAN NO. 2 relay holder) - Body ground | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Check the terminals of the relay for deformation and corrosion.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Check that each connector between the BATT FAN NO. 2 relay and battery cooling blower assembly (No. 1) is not loose or disconnected.
Before disconnecting the connector, check that it is not loose or disconnected.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | BATT FAN NO. 2 Relay Holder |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (BATT FAN NO. 2 relay holder) - M50-1 (IG1) | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Check that each connector between the BATT FAN NO. 2 relay and battery cooling blower assembly (No. 1) is not loose or disconnected.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
Install the BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the BATT FAN NO. 2 fuse and BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | BATT FAN NO. 2 Fuse Holder |
| *3 | BATT FAN NO. 2 Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BATT FAN NO. 2 fuse holder) - Terminals other than 3 (BATT FAN NO. 2 relay holder) and body ground | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Install the BATT FAN NO. 2 fuse and BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the BATT FAN NO. 2 relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | BATT FAN NO. 2 Relay Holder |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly (No. 1)) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (BATT FAN NO. 2 relay holder) - M50-1 (IG1) | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
Install the BATT FAN NO. 2 relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the rear floor silencer.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
Disconnect the M50 battery cooling blower assembly (No. 1) connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Component without harness connected
(Battery Cooling Blower Assembly (No. 1)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M50-1 (IG1) - M50-4 (GND1) and Body ground | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Reconnect the M50 battery cooling blower assembly (No. 1) connector.
Install the rear floor silencer.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY BLOWER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT