Refer to the description for P0D2D16.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 2WD)>P0D2D16
The MG ECU, which is built into in the inverter with converter assembly, controls motor (MG2) based on commands from the hybrid vehicle control ECU.
The hybrid vehicle control ECU monitors communication data and detects malfunctions.
A communication error between the MG ECU and the hybrid vehicle control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
(1 trip detection logic) |
·
Wire harness or connector ·
Inverter with converter assembly ·
Hybrid vehicle control ECU ·
PCU fuse |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
With ignition switch ON and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Remove the PCU fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | PCU Fuse |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| PCU fuse | Always | Below 1 Ω |
Install the PCU fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Turn the ignition switch to ON and wait for 2 minutes or more.
Check for Diagnosis Related Information and DTCs.
| Tester Display |
|---|
| Diagnosis Related Information |
| Result | Proceed to |
|---|---|
| P312387 is listed in Diagnosis Related Information or DTC P312387 is output. | A |
| P312387 is not listed in Diagnosis Information and DTC P312387 is not output. | B |
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for 2WD)>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 2WD)>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A55 inverter with converter assembly connector.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A55-9 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| A55-8 (GND2) - Body ground | Ignition switch off | Below 1 Ω |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A55-36 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| A55-35 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A55 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A55 inverter with converter assembly connector.
Disconnect the A31 hybrid vehicle control ECU connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-14 (HMCL) - Body ground | Ignition switch ON | Below 1 V |
| A31-4 (HMCH) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the hybrid vehicle control ECU connector and the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A55-4 (HMCL) - A31-14 (HMCL) | Ignition switch off | Below 1 Ω |
| A55-3 (HMCH) - A31-4 (HMCH) | Ignition switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A55-4 (HMCL) or A31-14 (HMCL) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A55-3 (HMCH) or A31-4 (HMCH) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
As there might be an intermittent malfunction, inspect the following items even if the measured resistance is as specified.
Check that each connector between the inverter with converter assembly and hybrid vehicle control ECU is not loose or disconnected.
Reconnect the A31 hybrid vehicle control ECU connector.
Reconnect the A55 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A55 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-14 (HMCL) - A31-4 (HMCH) | Ignition switch off | 110 to 130 Ω |
Reconnect the A55 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | PCU Fuse |
Replace the PCU fuse.
Turn the ignition switch to ON (READY).
Check if there is an open circuit in the PCU fuse in the No. 5 floor relay block and No. 5 floor junction block assembly.
There is no open circuit in the PCU fuse.
If the fuse does not become open again after turning the ignition switch to ON (READY), it can be assumed that the previous fuse failed due to age.
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the PCU fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Disconnect the A55 inverter with converter assembly connector.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | PCU Fuse Holder |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A55-36 (+B), A55-35 (+B2) or 2 (PCU fuse holder) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Reconnect the A55 inverter with converter assembly connector.
Install the PCU fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT