If the ignition switch is ON, the hybrid vehicle control ECU applies current to the MREL terminal to turn the IGCT relay on. This supplies power to the +B1 and +B2 terminals.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-11 (+B1) - Body ground | Ignition switch ON | 11 to 14 V |
| H67-1 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
Turn the ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A32 and H67 hybrid vehicle control ECU connectors.
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H67-3 (E1) - Body ground | Always | Below 1 Ω |
| A32-12 (E01) - Body ground | Always | Below 1 Ω |
| A32-11 (E02) - Body ground | Always | Below 1 Ω |
| A32-34 (E12) - Body ground | Always | Below 1 Ω |
Reconnect the A32 and H67 hybrid vehicle control ECU connectors.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-5 (MREL) - Body ground | Ignition switch ON | 11 to 14 V |
Turn the Ignition switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT NO. 1 Fuse |
Remove the IGCT NO. 1 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 1 fuse | Always | Below 1 Ω |
Install the IGCT NO. 1 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT-IG Fuse |
Remove the IGCT-IG fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT-IG fuse | Always | Below 1 Ω |
Install the IGCT-IG fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT Relay |
Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | IGCT Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
Install the IGCT relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A31 and H67 hybrid vehicle control ECU connectors.
Remove the IGCT NO. 1 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | IGCT NO. 1 Fuse Holder |
| *a | Front view of wire harness connectors
(to Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-11 (+B1) - 2 (IGCT NO. 1 fuse holder) | Always | Below 1 Ω |
| H67-1 (+B2) - 2 (IGCT NO. 1 fuse holder) | Always | Below 1 Ω |
Reconnect the A31 and H67 hybrid vehicle control ECU connectors.
Install the IGCT NO. 1 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT-IG fuse, IGCT NO. 1 fuse and IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT-IG Fuse Holder |
| *3 | IGCT NO. 1 Fuse Holder |
| *4 | IGCT Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (IGCT relay holder) - 2 (IGCT-IG fuse holder) | Always | Below 1 Ω |
| 5 (IGCT relay holder) - 1 (IGCT NO. 1 fuse holder) | Always | Below 1 Ω |
Install the IGCT-IG fuse, IGCT NO. 1 fuse and IGCT relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A31 hybrid vehicle control ECU connector.
Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | IGCT Relay Holder |
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-5 (MREL) - 1 (IGCT relay holder) | Always | Below 1 Ω |
| A31-5 (MREL) or 1 (IGCT relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
Install the IGCT relay.
Reconnect the A31 hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (IGCT relay holder) - Body ground | Always | Below 1 Ω |
Install the IGCT relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT NO. 1 fuse from the No. 5 floor relay block and No. 5 floor junction block assembly.
Disconnect the A31 and H67 hybrid vehicle control ECU connectors.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly | *2 | IGCT NO. 1 Fuse Holder |
| *a | Front view of wire harness connectors
(to Hybrid Vehicle Control ECU) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-11 (+B1) or 2 (IGCT NO. 1 fuse holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| H67-1 (+B2) or 2 (IGCT NO. 1 fuse holder) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the A31 and H67 hybrid vehicle control ECU connectors.
Install the IGCT NO. 1 fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the IGCT-IG fuse, IGCT NO. 1 fuse and IGCT relay from the No. 5 floor relay block and No. 5 floor junction block assembly.
| *1 | No. 5 Floor Relay Block and No. 5 Floor Junction Block Assembly |
| *2 | IGCT-IG Fuse Holder |
| *3 | IGCT NO. 1 Fuse Holder |
| *4 | IGCT Relay Holder |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (IGCT relay holder) or 2 (IGCT-IG fuse holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| 5 (IGCT relay holder) or 1 (IGCT NO. 1 fuse holder) - Body ground and other terminals | Always | 10 kΩ or higher |
Install the IGCT-IG fuse, IGCT NO. 1 fuse and IGCT relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT