MALFUNCTION DESCRIPTION
This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the rear motor (MGR) has been detected. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter | Inverter with converter assembly internal circuit malfunction |
| Rear traction motor with transaxle assembly | ·
Rear motor (MGR) internal malfunction (entry of foreign matter, etc.) ·
Rear motor (MGR) permanent magnet magnetic force deterioration ·
Open or short circuit in the rear motor coils |
| Inverter low-voltage circuit | The connectors are not connected properly |
| HV floor under wire (rear traction motor cable) | ·
Defective HV floor under wire (rear traction motor cable) connection condition ·
Open circuit or poor insulation in HV floor under wire (rear traction motor cable) |
| Hybrid vehicle control ECU | Hybrid vehicle control ECU internal circuit malfunction |
For a description of the rear motor (MGR).
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>P0A9000
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A9100 | Drive Motor "B" Performance | Rear motor magnetic force deterioration:
Decrease in the magnetic force of the rear motor (MGR) is detected. (1 trip detection logic) |
·
Rear traction motor with transaxle assembly ·
HV floor under wire (rear traction motor cable) ·
Inverter with converter assembly ·
Wire harness or connector ·
Hybrid vehicle control ECU |
Comes on | Master Warning:
Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and turn the GTS on.
Turn the ignition switch to ON (READY).
Drive the vehicle until the cumulative traveling time driving at a vehicle speed of 40 km/h (25 mph) or more is a few minutes. (It is not necessary to drive continuously at 40 km/h (25 mph) or more.)
Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Rear Motor High-voltage Circuit.
Refer to the wiring diagram for the Shut Down Signal Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Go to Motor Generator Control System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD)>P0A9100
For the P0A9100 inspection procedures, refer to the Motor Generator Control System section.
| Result |
|---|
| NEXT |
NEXT