CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Reconnect the instrument panel junction block assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| MB-11 (GND1) - Body ground | Ground | Always | Below 1 Ω |
| H42-19 (GND2) - Body ground | Ground | Always | Below 1 Ω |
| MB-30 (ACC) - Body ground | ACC power supply | Ignition switch ACC | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| MB-31 (BECU) - Body ground | Auxiliary battery power supply | Ignition switch off*1
Always*2 |
11 to 14 V |
| MB-32 (IG) - Body ground | IG power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
*1: for HV Model
*2: for Gasoline Model
Install the main body ECU (multiplex network body ECU) to the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>INSTALLATION
Measure the voltage and check for pulses according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| 4C-29 (BZR) - Body ground* | Wireless door lock buzzer output | Active Test Wireless Buzzer is OFF | Below 1 V |
| Active Test Wireless Buzzer is ON | Pulse generation
(frequency: 2 kHz, high voltage: 11 to 14 V, low voltage: below 1 V) |
*: w/ Wireless Door Lock Buzzer Answer-back Function
CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
| *A | for Gasoline Model | - | - |
Disconnect the H48 certification ECU (smart key ECU assembly) connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| H48-4 (+B) - Body ground | Auxiliary battery power supply | Ignition switch off*1
Always*2 |
11 to 14 V |
| H48-18 (E) - Body ground | Ground | Always | Below 1 Ω |
*1: for HV Model
*2: for Gasoline Model
Reconnect the H48 certification ECU (smart key ECU assembly) connector.
Check for pulses according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| M5-18 (RCO) - H48-18 (E) | Output to door control receiver
(Power supply for door control receiver. Certification ECU (smart key ECU assembly) outputs 5 V when receiver starts operating.) |
Procedure:
1.
Turn ignition switch off 2.
Bring electrical key transmitter sub-assembly outside detection area but within wireless function operational area 3.
Press lock or unlock switch of electrical key transmitter sub-assembly |
Plus generation (See waveform 1) |
| M5-19 (RDAM) - H48-18 (E) | Door control receiver communication circuit | Procedure:
1.
Turn ignition switch off 2.
Lock all doors 3.
Bring electrical key transmitter sub-assembly outside detection area but within wireless function operational area 4.
Press lock or unlock switch of electrical key transmitter sub-assembly |
Plus generation (See waveform 2) |
| M5-20 (CSEL) - H48-18 (E) | Communication channel switching circuit | Procedure:
1.
Turn ignition switch off 2.
Close all doors |
No pulse generation → Pulse generation |
| *a | Before lock or unlock switch of electrical key transmitter sub-assembly pressed |
| *b | After lock or unlock switch of electrical key transmitter sub-assembly pressed |
Using an oscilloscope, check waveform 1.
The oscilloscope waveform shown in the illustration is an example for reference only. Noise, chattering, etc. are not shown.
| Item | Content |
|---|---|
| Tester connection | M5-18 (RCO) - H48-18 (E) |
| Tool setting | 2 V/DIV., 500 ms/DIV. |
| Condition | Procedure:
1.
Turn ignition switch off 2.
Bring electrical key transmitter sub-assembly outside detection area but within wireless function operational area 3.
Press lock or unlock switch of electrical key transmitter sub-assembly |
| *a | Before lock or unlock switch of electrical key transmitter sub-assembly pressed |
| *b | After lock or unlock switch of electrical key transmitter sub-assembly pressed |
Using an oscilloscope, check waveform 2.
The oscilloscope waveform shown in the illustration is an example for reference only. Noise, chattering, etc. are not shown.
| Item | Content |
|---|---|
| Tester connection | M5-19 (RDAM) - H48-18 (E) |
| Tool setting | 5 V/DIV., 500 ms/DIV. |
| Condition | Procedure:
1.
Turn ignition switch off 2.
Lock all doors 3.
Bring electrical key transmitter sub-assembly outside detection area but within wireless function operational area 4.