Home › Vehicle Exterior › DOOR / HATCH › POWER BACK DOOR SYSTEM › from 2020.11
RM37A0E _59 Vehicle Exterior _086885 DOOR / HATCH _0418593 POWER BACK DOOR SYSTEM U

DOOR / HATCH  POWER BACK DOOR SYSTEM  TERMINALS OF ECU  


CHECK MULTIPLEX NETWORK DOOR ECU


B426088N24
2.677,0.375 3.052,0.625 0.375,0.25 4.51,0.365 4.885,0.615 0.375,0.25 2.729,0.406 3.188,0.604 0.458,0.198 10 false W18 4.552,0.396 5.01,0.594 0.458,0.198 10 false W19

a.

Disconnect the W18 and W19 multiplex network door ECU connectors.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
W18-20 (ECUB) - Body ground Auxiliary battery power supply Ignition switch off*1
Always*2
11 to 14 V
W18-18 (IG) - Body ground IG power supply Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
W19-1 (B) - Body ground Auxiliary battery power supply Ignition switch off*1
Always*2
11 to 14 V
W19-10 (GND) - Body ground Body ground Always Below 1 Ω

*1: for HV Model

*2: for Gasoline Model



c.

Reconnect the W18 and W19 multiplex network door ECU connectors.


d.

Measure the voltage and check for pulses according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
W18-1 (DS1) - Body ground Power back door unit assembly set LH (door sensor) signal Power back door not operating 7 V or higher
Power back door operating Pulse generation
(See waveform 1)
W18-2 (DS2) - Body ground Power back door unit assembly set LH (door sensor) signal Power back door not operating 7 V or higher
Power back door operating Pulse generation
(See waveform 2)
W18-3 (DS12) - Body ground Power back door unit assembly set RH (door sensor) signal Power back door not operating 7 V or higher
Power back door operating Pulse generation
(See waveform 1)
W18-4 (DS22) - Body ground Power back door unit assembly set RH (door sensor) signal Power back door not operating 7 V or higher
Power back door operating Pulse generation
(See waveform 2)
W18-5 (DSV2) - Body ground Power back door unit assembly set RH (door sensor) power supply Always 7 V or higher
W18-6 (OSR) - W18-24 (OSE) Power back door sensor assembly RH signal Power back door sensor assembly RH not pressed 4 to 6 V
Power back door sensor assembly RH pressed Below 1 V
W18-8 (BDDN) - Body ground No. 1 power back door control switch No. 1 power back door control switch on Below 1 V
No. 1 power back door control switch off Pulse generation
W18-12 (LIB) - Body ground Back door lock signal Back door is locked Below 1 V
Back door is unlocked 11 to 14 V
W18-14 (KSIN) - Body ground* Kick detection signal Kick door control sensor not detecting a foot → detecting a foot Pulse generation
(See waveform 3)
W18-16 (BZR+) - Body ground Wireless door lock buzzer signal Active Test PBD Buzzer is ON Pulse generation
(frequency: 2 kHz, high voltage: 11 to 14 V, low voltage: below 1 V)
Active Test PBD Buzzer is OFF Below 1 V
W18-19 (DSG2) - Body ground Power back door unit assembly set RH (door sensor) ground Always Below 1 V
W18-21 (DSG) - Body ground Power back door unit assembly set LH (door sensor) ground Always Below 1 V
W18-25 (DSV) - Body ground Power back door unit assembly set LH (door sensor) power supply Always 7 V or higher
W18-26 (OSL) - W18-24 (OSE) Power back door sensor assembly LH signal Power back door sensor assembly LH not pressed 4 to 6 V
Power back door sensor assembly LH pressed Below 1 V
W19-4 (DC+) - W19-3 (DC-) Back door lock with courtesy light switch assembly (back door lock motor) circuit Back door lock motor operating 11 to 14 V
Back door lock motor not operating Below 1 V

*: w/ Hands Free Power Back Door


i.
E357125N01
2.854,1.76 3.313,1.958 0.458,0.198 10 false GND

Using an oscilloscope, check waveform 1.

Waveform 1 (Reference)
Item Condition
Tester Connection
·

W18-1 (DS1) - Body ground

·

W18-3 (DS12) - Body ground


Tool setting 2 V/DIV., 2 ms/DIV.
Vehicle condition Power back door operating

HINT:

The period changes in accordance with the speed at which the power back door is opened and closed.



ii.
E357126N01
2.854,1.75 3.313,1.948 0.458,0.198 10 false GND

Using an oscilloscope, check waveform 2.

Waveform 2 (Reference)
Item Condition
Tester Connection
·

W18-2 (DS2) - Body ground

·

W18-4 (DS22) - Body ground


Tool setting 2 V/DIV., 2 ms/DIV.
Vehicle condition Power back door operating

HINT:

The period changes in accordance with the speed at which the power back door is opened and closed.



iii.
E356634C03
0.313,1.625 0.771,1.823 0.458,0.198 10 false GND 1.823,1.948 2.281,2.146 0.458,0.198 10 false *a
*a Kick detection signal


Using an oscilloscope, check waveform 3.

Waveform 3 (Reference)
Item Condition
Tester Connection W18-14 (KSIN) - Body ground*
Tool setting 2 V/DIV., 50 ms/DIV.
Vehicle condition Kick door control sensor not detecting a foot → detecting a foot

*: w/ Hands Free Power Back Door





CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)


B506743C05
2.083,0.552 2.49,0.792 0.406,0.24 4.531,0.542 4.938,0.781 0.406,0.24 3.25,0.552 3.656,0.792 0.406,0.24 3.365,0.573 3.677,0.771 0.313,0.198 10 false M5 4.615,0.573 4.927,0.771 0.313,0.198 10 false H48 2.167,0.583 2.625,0.781 0.458,0.198 10 false A19 2.542,0.573 2.854,0.771 0.313,0.198 10 false *A
*A for Gasoline Model - -


a.

Disconnect the H48 certification ECU (smart key ECU assembly) connector.


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
H48-4 (+B) - Body ground Auxiliary battery power supply Ignition switch off*1
Always*2
11 to 14 V
H48-18 (E) - Body ground Body ground Always Below 1 Ω

*1: for HV Model

*2: for Gasoline Model



c.

Reconnect the H48 certification ECU (smart key ECU assembly) connector.


d.

Measure the waveform according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
M5-26 (TSW5) - H48-18 (E) Back door opener switch assembly (open switch) signal Back door opener switch assembly (open switch) off → on Pulse generation (See waveform 1)

i.
B251023C22
1.208,0.5 2.333,0.125 2.333,0.125 1.677,0.5 false 0.188,1.198 0.521,1.396 0.333,0.198 10 false GND 2.375,0.063 2.708,0.26 0.333,0.198 10 false *a
*a Checking for switch on signal at short intervals


Using an oscilloscope, check the waveform.

Waveform 1 (Reference)
Item Content
Terminal No. (Symbol) M5-26 (TSW5) - H48-18 (E)
Tool Setting 2 V/DIV., 500 ms/DIV.
Condition Back door opener switch assembly (open switch) off → on




CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


B520311N39
1.125,3.25 1.563,3.5 0.438,0.25 3.156,3.219 3.594,3.469 0.438,0.25 5.448,3.208 5.885,3.458 0.438,0.25 1.698,4.573 2.135,4.823 0.438,0.25 5.385,4.573 5.823,4.823 0.438,0.25 1.104,6.167 1.542,6.417 0.438,0.25 3.667,6.125 4.104,6.375 0.438,0.25 5.292,6.198 5.729,6.448 0.438,0.25 6.313,6.198 6.75,6.448 0.438,0.25 3.365,7.646 3.802,7.896 0.438,0.25 1.656,1.208 1.958,1.208 false 1.667,1.552 1.969,1.552 false 1.667,1.875 1.969,1.875 false 4.042,0.792 4.042,0.313 4.042,0.313 4.229,0.313 false 3.469,7.677 3.781,7.875 0.313,0.198 10 false MB 4.292,0.219 4.604,0.417 0.313,0.198 10 false MB 2.042,1.135 2.354,1.333 0.313,0.198 10 false H42 2.042,1.479 2.354,1.677 0.313,0.198 10 false H43 2.042,1.802 2.354,2 0.313,0.198 10 false H44 0.865,1.073 1.177,1.271 0.313,0.198 10 false 4D 0.865,1.656 1.177,1.854 0.313,0.198 10 false 4C 0.875,2.021 1.188,2.219 0.313,0.198 10 false 4E 0.896,2.25 1.208,2.448 0.313,0.198 10 false 4F 5.844,1.146 6.156,1.344 0.313,0.198 10 false 4B 5.844,1.76 6.156,1.958 0.313,0.198 10 false 4A 1.229,3.281 1.542,3.479 0.313,0.198 10 false H44 3.25,3.25 3.563,3.448 0.313,0.198 10 false H43 5.531,3.24 5.844,3.438 0.313,0.198 10 false H42 1.833,4.604 2.146,4.802 0.313,0.198 10 false 4A 1.24,6.198 1.552,6.396 0.313,0.198 10 false 4C 3.813,6.156 4.125,6.354 0.313,0.198 10 false 4D 5.427,6.219 5.74,6.417 0.313,0.198 10 false 4F 6.448,6.229 6.76,6.427 0.313,0.198 10 false 4E 5.51,4.604 5.823,4.802 0.313,0.198 10 false 4B

a.

Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL


b.

Reconnect the instrument panel junction block assembly connectors.


c.

Measure the resistance and voltage according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
MB-31 (BECU) - Body ground Auxiliary battery power supply Ignition switch off*1
Always*2
11 to 14 V
MB-32 (IG) - Body ground Ignition power supply (IG signal) Ignition switch off Below 1 V
Ignition switch ON 11 to 14 V
MB-30 (ACC) - Body ground Ignition power supply (ACC signal) Ignition switch off Below 1 V
Ignition switch ACC 11 to 14 V
MB-11 (GND1) - Body ground Ground Always Below 1 Ω
H42-19 (GND2) - Body ground Ground Always Below 1 Ω
MB-4 (BCTY) - Body ground Back door courtesy light switch input Back door closed 10 kΩ or higher
Back door open Below 1 Ω

*1: for HV Model

*2: for Gasoline Model



d.

Install the main body ECU (multiplex network body ECU) to instrument panel junction block assembly.

Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>INSTALLATION


e.

Measure the voltage and check for pulses according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
H44-4 (PBDS) - Body ground Power back door control switch signal Power back door control switch off Pulse generation
Power back door control switch on Below 1 V
H42-13 (LSBO) - Body ground Back door lock signal Back door is locked Below 1 V
Back door is unlocked 11 to 14 V
4C-29 (BZR) - Body ground Wireless door lock buzzer signal Wireless door lock buzzer not operating Below 1 V
Wireless door lock buzzer operating Pulse generation