Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model) › from 2020.11
RM37A0E _54 Brake _086868 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0421002 ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for HV Model) C

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for HV Model)  C050614  Right Front Wheel Speed Sensor Circuit Short to Ground or Open  


DESCRIPTION

Refer to DTC C050612.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model)>C050612

DTC No. Detection Item DTC Detection Condition Trouble Area Note
C050614 Right Front Wheel Speed Sensor Circuit Short to Ground or Open An open in the speed sensor signal circuit continues for 0.5 seconds or more.
·

Front speed sensor RH

·

Wire harness and connector

·

No. 2 skid control ECU (brake actuator assembly)


Output ECU: No. 2 skid control ECU (brake actuator assembly)

CAUTION / NOTICE / HINT

NOTICE:
·

After replacing the No. 2 skid control ECU (brake actuator assembly), perform "Calibration".

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model)>UTILITY

·

After replacing or removing and installing a speed sensor, perform Dealer Mode (Signal Check) inspection to confirm that the speed sensors are operating correctly.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model)>TEST MODE PROCEDURE



PROCEDURE

1.READ VALUE USING GTS (MOMENTARY INTERRUPTION)
a.

Select the line graph display on the GTS.


b.

Check for any momentary interruption in the wire harness and connector.

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for HV Model)>DATA LIST / ACTIVE TEST

Chassis > Brake/EPB > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
FR Speed Open Front speed sensor RH open detection Normal / Under intermittent Normal: Normal
Under intermittent: Momentary interruption
-
FR Speed Sensor Voltage Open Front speed sensor RH voltage open detection Normal / Under intermittent Normal: Normal
Under intermittent: Momentary interruption
-
Chassis > Brake/EPB > Data List
Tester Display
FR Speed Open
FR Speed Sensor Voltage Open
50003 435 101,110
OK:

Normal (There are no momentary interruptions.)


NOTICE:

Perform the above inspection before removing the sensor and connector.



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (FRONT SPEED SENSOR RH - BRAKE ACTUATOR ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (FRONT SPEED SENSOR RH - BRAKE ACTUATOR ASSEMBLY)
a.

Turn the ignition switch off.


b.

Make sure that there is no looseness at the locking part and the connecting part of the connectors.

OK:

The connector is securely connected.



c.

Disconnect the A40 front speed sensor RH connector.


d.

Disconnect the A57 No. 2 skid control ECU (brake actuator assembly) connector.


e.

Check both the connector case and the terminals for deformation and corrosion.

OK:

No deformation or corrosion.



f.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A40-1 (FR+) - A57-7 (FR+) Always Below 1 Ω
A40-1 (FR+) or A57-7 (FR+) - Body ground Always 10 kΩ or higher
A40-2 (FR-) - A57-6 (FR-) Always Below 1 Ω
A40-2 (FR-) or A57-6 (FR-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT BRAKE ACTUATOR ASSEMBLY (SENSOR POWER SOURCE CIRCUIT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT BRAKE ACTUATOR ASSEMBLY (SENSOR POWER SOURCE CIRCUIT)
a.
C380194C35
1.49,0.719 1.906,0.969 0.417,0.25 2.406,2.229 1.865,1.625 true 0.354,0.323 0.667,0.521 0.313,0.198 10 false *a 1.573,0.76 1.885,0.958 0.313,0.198 10 false A40 2.365,2.271 2.771,2.51 0.406,0.24 10 false FR+
*a Front view of wire harness connector
(to Front Speed Sensor RH)


Reconnect the A57 No. 2 skid control ECU (brake actuator assembly) connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A40-1 (FR+) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

NG