Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for Gasoline Model) › from 2020.11
RM37A0E _54 Brake _086868 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0420942 ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for Gasoline Model) C

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  ELECTRONICALLY CONTROLLED BRAKE SYSTEM(for Gasoline Model)  C052C1C  ABS Pump Motor Control Circuit Voltage Out of Range  


DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area
C052C1C ABS Pump Motor Control Circuit Voltage Out of Range When the +BS terminal voltage is from 9.5 to 17.4 V with the motor relay and motor fail safe relay OFF, an open or short in motor circuit continues for 2 seconds or more.
·

Skid control ECU (brake actuator assembly)

·

Wire harness and connector



CAUTION / NOTICE / HINT

NOTICE:

After replacing the skid control ECU (brake actuator assembly), perform "Calibration".

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for Gasoline Model)>UTILITY


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (GND2 TERMINAL)
a.

Make sure that there is no looseness at the locking part and the connecting part of the connectors.

OK:

The connector is securely connected.



b.

Disconnect the A39 skid control ECU (brake actuator assembly) connector.


c.

Check both the connector case and the terminals for deformation and corrosion.

OK:

No deformation or corrosion.



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A39-30 (GND2) - Body ground 1 minute or more after disconnecting the cable from the negative (-) auxiliary battery terminal Below 1 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR