The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during instrument panel passenger airbag assembly removal/installation are shown below.
After the ignition switch is turned off, the radio and display receiver assembly or the radio receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 120 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.
1. PRECAUTION
Be sure to read Precaution thoroughly before servicing.
Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
2.REMOVE TELEMATICS TRANSCEIVER WITH BRACKET (w/ Telematics Transceiver)
82142A
3.DISCONNECT NO. 2 INSTRUMENT PANEL WIRE
Check that the ignition switch is off.
Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
Disconnect the No. 2 instrument panel wire.
When disconnecting any airbag connector, take care not to damage the airbag wire harness.
Refer to How to Connect or Disconnect Airbag Connector.
4.REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
73960A
5.REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY
|
Deployment Side |
When storing the instrument panel passenger airbag assembly, keep the airbag deployment side facing upward.
Remove the 2 screws.
Pry back the passenger airbag door retainer to disengage the 3 hooks.
Do not damage the deployment surface of the instrument panel passenger airbag assembly.
Disengage the 3 hooks to remove the instrument panel passenger airbag assembly from the instrument panel safety pad sub-assembly.
82142A
6.REMOVE NO. 2 INSTRUMENT PANEL WIRE
Separate the No. 2 instrument panel wire from the wire harness clamp.
Disconnect the 2 airbag connectors to remove the No. 2 instrument panel wire from the instrument panel passenger airbag assembly.
When disconnecting any airbag connector, take care not to damage the airbag wire harness.
Refer to How to Connect or Disconnect Airbag Connector.