Home › Power Source / Network › 2GR-FKS (BATTERY / CHARGING) › GENERATOR › from 2020.11
RM37A0E _57 Power Source / Network _086881 2GR-FKS BATTERY / CHARGING _0419980 GENERATOR A

2GR-FKS BATTERY / CHARGING  GENERATOR  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during generator assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link

*1: Learning can also be performed using the GTS.

Click here(Click here)

Battery terminal is disconnected/reconnected Idle the engine for approximately 5 to 60 minutes or drive the vehicle until stop and start control is permitted Stop and Start System (Click here)
Perform steering sensor zero point calibration Lane Control System (Click here)
Parking Support Brake System*1
Pre-collision System
Memorize steering angle neutral point Parking Assist Monitor System (Click here)
Panoramic View Monitor System (Click here)
Initialize back door lock Power Door Lock Control System (Click here)
Reset back door close position Power Back Door System (Click here)

NOTICE:

After the ignition switch is turned off, the radio and display receiver assembly or the radio receiver assembly records various types of memory and settings. As a result, after turning the ignition switch off, make sure to wait at least 120 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.


PROCEDURE

Hide 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 16400 2.REMOVE RADIATOR ASSEMBLY

Hide 16361A 3.REMOVE V-RIBBED BELT

Hide 27020 4.REMOVE GENERATOR ASSEMBLY

a.
A454718

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator assembly connector.


d.

Disconnect the compressor assembly with magnetic clutch connector.


e.

Disengage the wire harness clamp.


f.
A454719

Type A:

i.

Remove the bolt.



g.

Type B:

i.
A454720

Remove the nut.



h.
A454721

Remove the 2 bolts and generator assembly.


i.
A454722

Remove the bolt and wire harness clamp bracket from the generator assembly.


j.
A396288

Remove the bolt and No. 1 generator bracket from the generator assembly.