DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass Air Flow Circuit Low |
DTC P0103 Mass Air Flow Circuit High |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | Open or short in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) |
|
| P0102 | Open in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) | |
| P0103 | Short in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) |
| Air Flow Value (gm/sec.) | Malfunction |
| Approximately 0.0 |
|
| 174.0 or more | Open in EVG circuit |

| 1.READ VALUE USING INTELLIGENT TESTER (MAF) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / MAF
Read the value.
| Air flow rate (gm/sec.) | Proceed to |
| 0.0 | A |
| 174.0 or more | B |
| Between 1 and 173.0 | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE CIRCUIT) |
Disconnect the A4 mass air flow meter connector.
![]() |
Turn the ignition switch ON.
Measure the voltage of the wire harness side connector and the body ground.
| Tester Connection | Specified Condition |
| +B (A4-1) - Body ground | 11 to 14 V |
|
| ||||
| OK | |
| 3.INSPECT ECM (VG VOLTAGE) |
![]() |
Start the engine.
Measure the voltage of the ECM connector.
| Tester Connection | Condition | Specified Condition |
| VG (E7-24) - EVG (E7-32) | Engine is idling | 0.5 to 3.4 V |
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A4 mass air flow meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| VG (A4-3) - VG (E7-24) | Below 1 Ω |
| E2G (A4-2) - EVG (E7-32) | Below 1 Ω |
| Tester Connection | Specified Condition |
| VG (A4-3) or VG (E7-24) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
![]() |
Disconnect the A4 MAF meter connector.
Remove the integration relay from the engine room junction block (Click here).
Disconnect the 1J integration relay connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| +B (A4-1) - 1J-5 | Below 1 Ω |
| Tester Connection | Specified Condition |
| +B (A4-1) or 1J-5 - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.INSPECT ECM (SENSOR GROUND) |
![]() |
Measure the resistance of the ECM connector and body ground.
| Tester Connection | Specified Condition |
| EVG (E7-32) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the A4 mass air flow meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| VG (A4-3) - VG (E7-24) | Below 1 Ω |
| E2G (A4-2) - EVG (E7-32) | Below 1 Ω |
| Tester Connection | Specified Condition |
| VG (A4-3) or VG (E7-24) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||