Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM (for RHD)

POWER WINDOW CONTROL SYSTEM (for RHD) > Driver Side Power Window does not Operate with Power Window Master Switch

for Preparation Click here


DESCRIPTION

If the manual UP / DOWN and AUTO DOWN functions do not operate, a malfunction may be present in the power window regulator master switch, power window regulator motor or wire harness.

WIRING DIAGRAM


B149728E02


INSPECTION PROCEDURE

1.INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY
B086400E01
  1. Remove the motor (Click here).

  1. Apply battery voltage to connector terminals 1 and 2.

    NOTICE:
    Do not apply battery voltage to any terminals except terminals 1 and 2.

  1. Check that the motor gear rotates smoothly as follows.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → 1
    Battery negative (-) → 2
    Motor gear rotates clockwise
    Battery positive (+) → 2
    Battery negative (-) → 1
    Motor gear rotates counterclockwise



NG
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY
OK


2.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (for Driver Switch)


    B085831E12
  1. Remove the master switch (Click here).

  1. Measure the resistance of the switch when the switch is operated.

    Standard resistance:

    Tester Connection
    Window Lock Switch Condition
    Driver Switch Condition
    Specified Condition
    3 (E) - 9 (DD), 4 (DU) - 6 (B)
    Always
    (ON / OFF)
    UP
    Below 1 Ω
    3 (E) - 4 (DU), 3 (E) - 9 (DD)
    Always
    (ON / OFF)
    OFF
    Below 1 Ω
    3 (E) - 4 (DU), 6 (B) - 9 (DD)
    Always
    (ON / OFF)
    DOWN
    Below 1 Ω
    3 (E) - 4 (DU), 6 (B) - 9 (DD)
    Always
    (ON / OFF)
    AUTO DOWN
    Below 1 Ω



NG
REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
OK


3.CHECK WIRE HARNESS (MASTER SWITCH - REGULATOR MOTOR)

B149729E02

  1. Disconnect the P6 master switch connector.

  1. Disconnect the P8 motor connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    P6-9 (DD) - P8-1
    Below 1 Ω
    P6-4 (DU) - P8-2
    Below 1 Ω
    P6-9 (DD) or P8-1 - Body ground
    10 kΩ or higher
    P6-4 (DU) or P8-2 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO POWER WINDOWS DO NOT OPERATE AT ALL