P0100 Mass Air Flow Circuit Malfunction
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Also covers:
- P0102 Mass or Volume Air Flow Circuit Low Input
- P0103 Mass or Volume Air Flow Circuit High Input
Versions by build date: Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The Mass Air Flow (MAF) meter measures the amount of air flowing through the throttle valve. The ECM uses this information to determine the fuel injection time and provide a proper air-fuel ratio. Inside the MAF meter, there is a heated platinum wire exposed to the flow of intake air.By applying a specific current to the wire, the ECM heats this wire to a given temperature. The flow of incoming air cools the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components in the MAF meter. The voltage level is proportional to the air flow through the sensor. The ECM interprets this voltage as the intake air amount.
The circuit is constructed so that the platinum hot wire and temperature sensor provide a bridge circuit, with the power transistor controlled so that the potential of A and B remains equal to maintain the set temperature.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0100 |
When MAF meter circuit has open or short for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
| P0102 |
When MAF meter circuit has open for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
| P0103 |
When MAF meter circuit has short for more than 3 seconds under 2,000 rpm engine speed (1 trip detection logic) |
|
- HINT:
- When DTC P0100, P0102 or P0103 is detected, check the air-flow ratio by entering the following menus on the intelligent tester: Powertrain / Engine / Data List / MAF.
Air Flow Rate (gm/s)
Malfunction
Approximately 0.0
- Open in MAF meter power source circuit
- Open or short in VG circuit
167.5 or more
Open in EVG circuit
- Open in MAF meter power source circuit
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- If the ECM is replaced, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. READ VALUE USING INTELLIGENT TESTER (MAF) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the intelligent tester ON.
Enter the following menus: Powertrain / Engine / Data List / MAF.
Read the values.
- Result:
Air flow rate (gm/s)
Proceed to
Approximately 0.0
A
167.5 or more
B
Between 1 and 167.4*
C
- HINT:
- *: The value must change when the throttle valve is opened or closed.
|
|
||||
|
|
||||
| A | |
| 2. CHECK MASS AIR FLOW METER (POWER SOURCE CIRCUIT) |
Disconnect the A4 MAF meter connector.

Turn the ignition switch ON.
Measure the voltage between the terminal of the wire harness side connector and the body ground.
- Standard voltage:
Tester Connection
Specified Condition
A4-1 (+B) - Body ground
11 to 14 V
|
|
||||
| OK | |
| 3. CHECK ECM (VG VOLTAGE) |
Start the engine.

Measure the voltage of E7 the ECM connector.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E7-24 (VG) - E7-32 (EVG)
Engine idling
0.5 to 3.4 V
- HINT:
- The A/C switch should be turned OFF.
|
|
||||
| NG | |
| 4. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the A4 MAF meter connector.

Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
A4-3 (VG) - E7-24 (VG)
Below 1 Ω
A4-2 (E2G) - E7-32 (EVG)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
A4-3 (VG) or E7-24 (VG) - Body ground
10 kΩ or higher
A4-2 (E2G) or E7-32 (EVG) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - NO. 1 INTEGRATION RELAY (MAIN RELAY)) |
![]() ![]() |
Disconnect the A4 MAF meter connector.
Remove the No. 1 integration relay from the engine room junction block (Click here).
Disconnect the 1J No. 1 integration relay connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
A4-1 (+B) - 1J-5
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
A4-1 (+B) or 1J-5 - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 6. CHECK ECM (SENSOR GROUND) |
![]() ![]() |
Measure the resistance of the E7 ECM connector and body ground.
- Standard resistance:
Tester Connection
Specified Condition
E7-32 (EVG) - Body ground
Below 1 Ω
|
|
||||
| OK | |
| 7. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER- ECM) |
![]() ![]() |
Disconnect the A4 MAF meter connector.
Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
A4-3 (VG) - E7-24 (VG)
Below 1 Ω
A4-2 (E2G) - E7-32 (EVG)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
A4-3 (VG) or E7-24 (VG) - Body ground
10 kΩ or higher
A4-2 (E2G) or E7-32 (EVG) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||