ECM Power Source Circuit
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
When the ignition switch is turned ON, the battery voltage is applied to terminal IGSW of the ECM. The ECM "MREL" output signal causes current to flow to the MAIN relay coil, closing the contacts of the EFI relay and supplying power to terminal +B of the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK ECM (+B VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connector.
- Standard voltage:
Tester Connection
Specified Condition
E20-12 (+B) - E23-14 (E1)
9 to 14 V
|
|
||||
| NG | |
| 2. CHECK WIRE HARNESS (ECM - BODY GROUND) |
![]() ![]() |
Disconnect the E23 ECM connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
Specified Condition
E23-14 (E1) - Body ground
Below 1 Ω
|
|
||||
| OK | |
| 3. CHECK ECM (IGSW VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connector.
- Standard voltage:
Tester Connection
Specified Condition
E20-14 (IGSW) - E23-14 (E1)
9 to 14 V
|
|
||||
| NG | |
| 4. INSPECT FUSE (IGN) |
![]() ![]() |
Remove the IGN fuse from the instrument panel junction block.
Measure the resistance of the IGN fuse.
- Standard resistance:
Tester Connection
Specified Condition
IGN fuse
Below 1 Ω
|
|
||||
| OK | |
| 5. INSPECT IGNITION SWITCH ASSEMBLY |
![]() ![]() |
Disconnect the ignition switch connector.
Measure the resistance of the ignition switch.
- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
5 (AM2) - 6 (IG2)
LOCK
10 kΩ or higher
5 (AM2) - 6 (IG2)
ON
Below 1 Ω
|
|
||||
| OK | ||
| ||
| 6. CHECK ECM (MREL VOLTAGE) |
![]() ![]() |
Turn the ignition switch ON.
Measure the voltage of the ECM connector.
- Standard voltage:
Tester Connection
Specified Condition
E20-3 (MREL) - E23-14 (E1)
9 to 14 V
|
|
||||
| OK | |
| 7. INSPECT FUSE (EFI) |
![]() ![]() |
Remove the EFI fuse from the engine room junction block.
Measure the resistance of the EFI fuse.
- Standard resistance:
Tester Connection
Specified Condition
EFI fuse
Below 1 Ω
|
|
||||
| OK | |
| 8. CHECK INTEGRATION NO.1 RELAY (MAIN RELAY) |
![]() ![]() |
Disconnect the 1J integration relay connector from the engine room junction block (Click here).
Measure the voltage of the integration relay.
- Standard voltage:
Tester Connection
Condition
Specified Condition
1J-4 - Body ground
Ignition switch ON
10 to 14 V
|
|
||||
| OK | |
| 9. CHECK WIRE HARNESS (INTEGRATION RELAY [MAIN RELAY] - ECM AND BODY GROUND) |
![]() ![]() |
Disconnect the 1J integration relay connector from the engine room junction block (Click here).
Disconnect the E20 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance:
Tester Connection
Specified Condition
1J-2 - E20-3 (MREL)
Below 1 Ω
1J-4 - E20-12 (+B)
Below 1 Ω
1J-3 - Body ground
Below 1 Ω
1J-2 or E20-3 (MREL) - Body ground
10 kΩ or higher
1J-4 or E20-12 (+B) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||