Power Windows do not Operate at All
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
If all of the power windows do not operate, the power window regulator master switch assembly may have no power or may be malfunctioning.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND) |
except Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHD Tester Connection
Switch Condition
Specified Condition
P4-9 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-9 (B) - Body ground
Ignition switch off
Below 1 V
for RHD Tester Connection
Switch Condition
Specified Condition
P4-9 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-9 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
P4-1 (E) - Body ground
Always
Below 1 Ω
for RHD Tester Connection
Condition
Specified Condition
P4-10 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *A
for LHD
*B
for RHD
*a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
for Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
P4-6 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-6 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
P4-3 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
w/ Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
P4-7 (BW) - Body ground
Always
11 to 14 V
P4-6 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-6 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
P4-1 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
|
|
||||
| OK | ||
| ||