2014 Hilux · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built Jun 2011 – Jul 2012

Versions by build date: Jun 2011 – Jul 2012 from Aug 2012


VISUALLY CHECK TURBOCHARGER SUB-ASSEMBLY

  1. A230524E01
    Check for deformation and cracks in the turbine wheel on the exhaust side.
    If the turbine wheel is cracked or deformed, replace the turbocharger sub-assembly.
    Text in Illustration 
    *1
    Turbine Wheel


INSPECT AXIAL PLAY OF TURBINE SHAFT

  1. A110335E01
    Move the turbine shaft in an axial direction and measure the axial play of the turbine shaft using a dial indicator.

    Maximum axial play:
    0.08 mm (0.0031 in.)

    NOTICE:
    Turbocharger sub-assembly and dial indicators are surely fixed when performing measurement.

    If the axial play is greater than the maximum, replace the turbocharger sub-assembly.


INSPECT RADIAL PLAY OF TURBINE SHAFT

  1. A110337
    Using a dial indicator, insert the needle of the dial indicator into the oil outlet hole, and set it in the center of the turbine shaft.

  1. Move the turbine shaft in a radial direction and measure the radial play of the turbine shaft.

    Maximum axial play:
    0.110 mm (0.0043 in.)

    If the radial play is greater than the maximum, replace the turbocharger sub-assembly.


CHECK TURBINE SHAFT ROTATION

  1. A110325
    Rotate the turbine wheel with your finger and check that it rotates smoothly.

    HINT:
    Even if it takes effort a little to rotate the turbine wheel, this is not a problem.

    If the turbine wheel does not rotate smoothly, replace the turbocharger sub-assembly.


INSPECT ACTUATOR AND WASTE GATE VALVE OPERATION

A099568
  1. Disconnect the actuator hose from the compressor housing.

  1. Using SST, apply pressure to the actuator.

    SST
    09992-00242  

    Valve opening pressure:
    Specified pressure* (See attached table below)

    NOTICE:
    Never apply more than predetermined maximum pressure* to the actuator.


    HINT:
    *: Valve opening pressure and predetermined maximum pressure above differ according to the turbocharger. For the specifications, see attached table below.
    Specifications: 
    Valve Opening Pressure
    (kPa: Gauge Pressure)
    Maximum Pressure
    (kPa: Gauge Pressure)
    Reference:
    Rod Stroke
    (mm)
    114
    136
    0.98 to 1.91

  1. Check that the actuator push rod moves and that the waste gate valve opens.
    If the rod does not move, replace the turbocharger sub-assembly.

  1. Reconnect the actuator hose to the compressor housing.

← REMOVAL (from Aug 2013)INSPECTION (from Aug 2012) →