2014 Hilux · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Jun 2011


INSPECT GENERATOR ROTOR ASSEMBLY

  1. Check the rotor for an open circuit.

    1. B003131E03
      Measure the resistance between the slip rings.

      Standard resistance:
      2.7 to 3.1 Ω at 20°C (68°F)

      If the result is not as specified, replace the generator rotor assembly.

  1. Check the rotor for a short circuit.

    1. B003132E03
      Measure the resistance between each slip ring and the rotor.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the generator rotor assembly.

  1. Check that the slip rings are not rough or scored.
    If they are rough or scored, replace the rotor.

  1. A038110E02
    Using a vernier caliper, measure the slip ring diameter.

    Standard diameter:
    14.2 to 14.4 mm (0.559 to 0.567 in.)

    Minimum diameter:
    12.8 mm (0.504 in.)

    If the diameter is less than the minimum, replace the rotor assembly.

  1. Inspect the bearing.

    1. Check that the bearing is not rough or worn.
      If necessary, replace the generator rotor.


INSPECT DRIVE END FRAME

  1. Check the stator for an open circuit.

    1. S004626E03
      Measure the resistance between the coil leads.

      Standard resistance:
      Below 1 Ω

      If the result is not as specified, replace the drive end frame assembly.

  1. Check the stator for a short circuit.

    1. S003922E03
      Measure the resistance between each coil lead and the drive end frame assembly.

      Standard resistance:
      10 kΩ or higher

      If the result is not as specified, replace the drive end frame assembly.

  1. Inspect the bearing.

    1. Check that the bearing is not rough or worn.
      If necessary, replace the drive end frame assembly.


INSPECT BRUSH HOLDER

  1. P013535E02
    Using a vernier caliper, measure the exposed brush length.

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)

    Minimum exposed length:
    1.5 mm (0.059 in.)

    If the exposed length is less than the minimum, replace the brush holder.


INSPECT GENERATOR HOLDER WITH RECTIFIER

  1. Check the positive terminal of the rectifier.

    1. P008486E02
      Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.

    2. Reverse the polarity of the tester probes and repeat the step above.

    3. Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩor higher.
      Check that there is a resistance of 10 kΩor higher.

  1. Check the negative terminal of the rectifier.

    1. P008487E02
      Using an ohmmeter, connect one tester probe to each negative (-) terminal and the other to each rectifier terminal.

    2. Reverse the polarity of the tester probes and repeat the step above.

    3. Check that one shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩor higher.
      Check that there is a resistance of 10 kΩor higher.
      If the result is not as specified, replace the generator holder with rectifier.


INSPECT REGULATOR

  1. B014407E02
    Using an ohmmeter, measure the resistance between terminals F and B.

    Standard:
    Below 1 Ω or 10 kΩ or higher

    HINT:
    When the ohmmeter's leads are initially touched to the regulator, one of the above values will be output. When the leads are reversed, the reading will change to the other value.

    If the result is not as specified, replace the regulator.

  1. B014408E02
    Using an ohmmeter, measure the resistance between terminals F and E.

    Standard:
    Below 1 Ω or 10 kΩ or higher

    HINT:
    When the ohmmeter's leads are initially touched to the regulator, one of the above values will be output. When the leads are reversed, the reading will change to the other value.

    If the result is not as specified, replace the regulator.

← DISASSEMBLY (from Jun 2011)REASSEMBLY (from Jun 2011) →