P0504 Brake Switch "A" / "B" Correlation
Diagnostic trouble codes · Vehicles built from Aug 2014
Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
In this system, the signals of the duplex type stop light switch (STP and ST1-) are used to judge whether the brake system is abnormal. When signals that indicate depressing and releasing the brake pedal are detected simultaneously, the ECM interprets this as a malfunction of the stop light switch.- HINT:
- Normal conditions are shown in the table below.
Signal
Brake Pedal Released
In Transition
Brake Pedal Depressed
STP
OFF
ON
ON
ST1-
ON
ON
OFF
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0504 |
Conditions (a), (b) and (c) continue for 0.5 seconds or more: (1 trip detection logic) (a) Ignition switch is ON (b) Brake pedal is released (c) STP signal is OFF when ST1- signal is OFF |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. CHECK OPERATION OF STOP LIGHT |
Check if the stop lights turn ON and OFF when the brake pedal is depressed and released.
- OK:
- Stop lights turn ON and OFF normally.
|
|
||||
| OK | |
| 2. CHECK STP SIGNAL |
Connect the intelligent tester to the DLC3.

Turn the ignition switch ON and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / Stop Light Switch.
Read the value.
- OK:
Brake Pedal
Specified Condition
Depressed
STP signal ON
Released
STP signal OFF
Measure the voltage of the ECM connectors.
- Standard voltage:
Tester Connection
Brake Pedal
Specified Condition
ST1- (E6-14) - E1 (E7-7)
Depressed
Below 1.5 V
ST1- (E6-14) - E1 (E7-7)
Released
7.5 to 14 V
|
|
||||
| NG | |
| 3. CHECK STOP LIGHT SWITCH ASSEMBLY |
Remove the stop light switch.

Measure the resistance of the stop light switch.
- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2
Pin not pushed
Below 1 Ω
3 - 4
Pin not pushed
10 kΩ or higher
1 - 2
Pin pushed
10 kΩ or higher
3 - 4
Pin pushed
Below 1 Ω
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH - ECM) |
Disconnect the S14 stop light switch connector.

Disconnect the E6 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
S14-1 - STP (E6-15)
Below 1 Ω
S14-4 - ST1- (E6-14)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
S14-1 or STP (E6-15) - Body ground
10 kΩ or higher
S14-4 or ST1- (E6-14) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||