2014 Hilux · Service Manual HEATER & AIR CONDITIONING SYSTEM

Blower Motor Circuit

Circuit diagnosis · Vehicles built from Aug 2013

Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 from Aug 2013

DESCRIPTION

E113414E09
The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier. Blower with fan motor sub-assembly speed signals are determined by changes in the duty ratio*.
The blower motor control controls the blower with fan motor sub-assembly speed. The blower motor control reads the signal from the air conditioning amplifier assembly and controls rotation and speed.

HINT:
*: The duty ratio is the ratio of the blower with fan motor sub-assembly on time (A) to the total of the blower with fan motor sub-assembly on and off time (A + B).


WIRING DIAGRAM

E225334E03

INSPECTION PROCEDURE

NOTICE:
Inspect the relays for circuits related to this system before performing the following inspection procedure.


1. PERFORM ACTUATOR CHECK
  1. Enter actuator check mode (Click here).

  1. Place your hand in front of a vent and check that the air flow level changes according to the display code.

    Display Code
    Blower Level
    0
    0
    1
    1
    2
    16
    3
    16
    4
    16
    5
    16
    6
    16
    7
    16
    8
    16
    9
    31

    OK:
    Blower level changes in accordance with each display code.

    HINT:
    The progression through the steps of the actuator check can be changed from automatic to manual by pressing the front DEF switch.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

2. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER AND BODY GROUND)
  1. Disconnect the B10 blower motor control connector.

  1. Disconnect the A44 air conditioning amplifier assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B10-3 (SI) - A44-2 (BLW)
    Always
    Below 1 Ω
    B10-4 (GND) - Body ground
    B10-3 (SI) - Body ground
    Always
    10 kΩ or higher
    B10-2 (+B) - Body ground
    B10-1 (VM) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3. INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY

  1. E218806
    Remove the blower with fan motor sub-assembly (Click here).

  1. Apply battery voltage to the blower with fan motor sub-assembly and check the operation of the blower motor.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 2
    Battery negative (-) → Terminal 1
    The blower motor operates smoothly



NG
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL AND BLOWER WITH FAN MOTOR - BATTERY)
  1. Disconnect the B10 blower motor control connector.

  1. Disconnect the B7 blower with fan motor sub-assembly connector.

  1. Measure the voltage and resistance according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B10-2 (+B) - Body ground
    1. Ignition switch ON
    2. Blower switch on (LO level)
    11 to 14 V
    1. Ignition switch ON
    2. Blower switch off
    Below 1 V
    B7-2 - Body ground
    1. Ignition switch ON
    2. Blower switch on (LO level)
    11 to 14 V
    1. Ignition switch ON
    2. Blower switch off
    Below 1 V

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B7-1 - Body ground
    Always
    10 kΩ or higher
    B7-2 - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BLOWER WITH FAN MOTOR)
  1. Disconnect the B10 blower motor control connector.

  1. Disconnect the B7 blower with fan motor sub-assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B10-1 (VM) - B7-1
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

  1. E165595E15
    Remove the air conditioning amplifier assembly with its connectors still connected (Click here).

  1. Using an oscilloscope, check the waveform of the amplifier.

    Measurement Condition 
    Item
    Content
    Tester Connection
    A44-2 (BLW) - Body ground
    Tool Setting
    1 V/DIV., 50 μsec./DIV.
    Condition
    Ignition switch ON, Blower switch on (LO level)

    OK:
    Waveform is as shown in the illustration.

    HINT:
    Waveform varies depending on the blower switch setting.

    Text in Illustration 
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

REPLACE BLOWER MOTOR CONTROL (Click here)