Driver Side Power Window Manual Function does not Operate with Power Window Master Switch
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
If the manual up/down function does not operate, a malfunction may be present in the power window regulator master switch assembly, front power window regulator motor assembly (for driver side)*1, front door window regulator sub-assembly (for driver side)*2 or wire harness.- *1: w/o Regulator
- *2: w/ Regulator
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND) |
except Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHD Tester Connection
Condition
Specified Condition
P4-9 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-9 (B) - Body ground
Ignition switch off
Below 1 V
for RHD Tester Connection
Condition
Specified Condition
P4-9 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-9 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
P4-1 (E) - Body ground
Always
Below 1 Ω
for RHD Tester Connection
Condition
Specified Condition
P4-10 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *A
for LHD
*B
for RHD
*a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
for Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
P4-6 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-6 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
P4-3 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
w/ Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
P4-7 (BW) - Body ground
Always
11 to 14 V
P4-6 (B) - Body ground
Ignition switch ON
11 to 14 V
P4-6 (B) - Body ground
Ignition switch off
Below 1 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
P4-1 (E) - Body ground
Always
Below 1 Ω
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
|
|
||||
| OK | |
| 2. CHECK FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR DRIVER SIDE) OR FRONT DOOR WINDOW REGULATOR SUB-ASSEMBLY (FOR DRIVER SIDE) |
except Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Using a service wire, connect the terminals according to the table below.
Check operation of the front power window regulator motor assembly (for driver side)*1 or front door window regulator sub-assembly (for driver side)*2.
- *1: w/ Regulator
- *2: w/o Regulator
- OK:
for LHD Tester Connection
Condition
Specified Condition
P4-3 (U) - P4-9 (B)
P4-4 (D) - Body ground
Always
Power window moves up
P4-3 (U) - Body ground
P4-9 (B) - P4-4 (D)
Always
Power window moves down
for RHD Tester Connection
Condition
Specified Condition
P4-2 (U) - P4-9 (B)
P4-5 (D) - Body ground
Always
Power window moves up
P4-2 (U) - Body ground
P4-9 (B) - P4-5 (D)
Always
Power window moves down
Text in Illustration *A
for LHD
*B
for RHD
*a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
- *1: w/ Regulator
for Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Using a service wire, connect the terminals according to the table below.
Check operation of the front power window regulator motor assembly (for driver side)*1 or front door window regulator sub-assembly (for driver side)*2.
- *1: w/ Regulator
- *2: w/o Regulator
- OK:
Tester Connection
Condition
Specified Condition
P4-4 (U) - P4-6 (B)
P4-9 (D) - Body ground
Always
Power window moves up
P4-4 (U) - Body ground
P4-6 (B) - P4-9 (D)
Always
Power window moves down
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
- *1: w/ Regulator
w/ Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.

Using a service wire, connect the terminals according to the table below.
Check operation of the front power window regulator motor assembly (for driver side)*1 or front door window regulator sub-assembly (for driver side)*2.
- *1: w/ Regulator
- *2: w/o Regulator
- OK:
Tester Connection
Condition
Specified Condition
P4-4 (U) - P4-7 (BW)
P4-9 (D) - Body ground
Always
Power window moves up
P4-4 (U) - Body ground
P4-7 (BW) - P4-9 (D)
Always
Power window moves down
Text in Illustration *a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)
- *1: w/ Regulator
|
|
||||
| OK | ||
| ||
| 3. CHECK POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
except Double Cab, w/o Jam Protection:
Remove the power window regulator master switch assembly with its connectors still connected.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHD Tester Connection
Condition
Specified Condition
3 (U) - 1(E)
Ignition switch ON, driver side power window switch off → up (manual operation)
Below 1 V → 11 to 14 V
3 (U) - 1(E)
Ignition switch ON, driver side power window fully open → driver side power window switch up (auto operation) → driver side power window fully closed
Below 1 V → 11 to 14 V → Below 1 V
5 (D) - 10 (E)
Ignition switch ON, driver side power window switch off → down (manual operation)
Below 1 V → 11 to 14 V
4 (D) - 1 (E)
Ignition switch ON, driver side power window fully closed → driver side power window switch down (auto operation) → driver side power window fully open
Below 1 V → 11 to 14 V → Below 1 V
for RHD Tester Connection
Condition
Specified Condition
2 (U) - 10 (E)
Ignition switch ON, driver side power window switch off → up (manual operation)
Below 1 V → 11 to 14 V
2 (U) - 10 (E)
Ignition switch ON, driver side power window fully open → driver side power window switch up (auto operation) → driver side power window fully closed
Below 1 V → 11 to 14 V → Below 1 V
5 (D) - 10 (E)
Ignition switch ON, driver side power window switch off → down (manual operation)
Below 1 V → 11 to 14 V
5 (D) - 10 (E)
Ignition switch ON, driver side power window fully closed → driver side power window switch down (auto operation) → driver side power window fully open
Below 1 V → 11 to 14 V → Below 1 V
Text in Illustration *A
for LHD
*B
for RHD
*a
Component with harness connected
(Power Window Regulator Master Switch Assembly)
for Double Cab, w/o Jam Protection:
Remove the power window regulator master switch assembly with its connectors still connected.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
4 (U) - 3 (E)
Ignition switch ON, driver side power window switch off → up (manual operation)
Below 1 V → 11 to 14 V
4 (U) - 3 (E)
Ignition switch ON, driver side power window fully open → driver side power window switch up (auto operation) → driver side power window fully closed
Below 1 V → 11 to 14 V → Below 1 V
9 (D) - 3 (E)
Ignition switch ON, driver side power window switch off → down (manual operation)
Below 1 V → 11 to 14 V
9 (D) - 3 (E)
Ignition switch ON, driver side power window fully closed → driver side power window switch down (auto operation) → driver side power window fully open
Below 1 V → 11 to 14 V → Below 1 V
Text in Illustration *a
Component with harness connected
(Power Window Regulator Master Switch Assembly)
w/ Jam Protection:
Remove the power window regulator master switch assembly with its connectors still connected.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
4 (U) - 1 (E)
Ignition switch ON, driver side power window switch off → up (manual operation)
Below 1 V → 11 to 14 V
4 (U) - 1 (E)
Ignition switch ON, driver side power window fully open → driver side power window switch up (auto operation) → driver side power window fully closed
Below 1 V → 11 to 14 V → Below 1 V
9 (D) - 1 (E)
Ignition switch ON, driver side power window switch off → down (manual operation)
Below 1 V → 11 to 14 V
9 (D) - 1 (E)
Ignition switch ON, driver side power window fully closed → driver side power window switch down (auto operation) → driver side power window fully open
Below 1 V → 11 to 14 V → Below 1 V
Text in Illustration *a
Component with harness connected
(Power Window Regulator Master Switch Assembly)
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH - FRONT POWER WINDOW REGULATOR MOTOR [FOR DRIVER SIDE] OR FRONT DOOR WINDOW REGULATOR [FOR DRIVER SIDE]) |
- *1: for LHD
- *2: for RHD
except Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.
w/o Regulator:
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
w/ Regulator:
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
P4-4 (D) - P5-1 (D)
Always
Below 1 Ω
P4-3 (U) - P5-2 (U)
Always
Below 1 Ω
P4-4 (D) or P5-1 (D) - Body ground
Always
10 kΩ or higher
P4-3 (U) or P5-2 (U) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
P4-5 (D) - P6-1 (D)
Always
Below 1 Ω
P4-2 (U) - P6-2 (U)
Always
Below 1 Ω
P4-5 (D) or P6-1 (D) - Body ground
Always
10 kΩ or higher
P4-2 (U) or P6-2 (U) - Body ground
Always
10 kΩ or higher
for Double Cab, w/o Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.
w/o Regulator:
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
w/ Regulator:
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
P4-9 (D) - P5-1 (D)
Always
Below 1 Ω
P4-4 (U) - P5-2 (U)
Always
Below 1 Ω
P4-9 (D) or P5-1 (D) - Body ground
Always
10 kΩ or higher
P4-4 (U) or P5-2 (U) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
P4-9 (D) - P6-1 (D)
Always
Below 1 Ω
P4-4 (U) - P6-2 (U)
Always
Below 1 Ω
P4-9 (D) or P6-1 (D) - Body ground
Always
10 kΩ or higher
P4-4 (U) or P6-2 (U) - Body ground
Always
10 kΩ or higher
w/ Jam Protection:
Disconnect the P4 power window regulator master switch assembly connector.
w/o Regulator:
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front power window regulator motor assembly (for driver side) connector.
w/ Regulator:
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
- Disconnect the P5*1 or P6*2 front door window regulator sub-assembly (for driver side) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
P4-9 (D) - P5-1 (D)
Always
Below 1 Ω
P4-4 (U) - P5-2 (U)
Always
Below 1 Ω
P4-9 (D) or P5-1 (D) - Body ground
Always
10 kΩ or higher
P4-4 (U) or P5-2 (U) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
P4-9 (D) - P6-1 (D)
Always
Below 1 Ω
P4-4 (U) - P6-2 (U)
Always
Below 1 Ω
P4-9 (D) or P6-1 (D) - Body ground
Always
10 kΩ or higher
P4-4 (U) or P6-2 (U) - Body ground
Always
10 kΩ or higher
| Result |
Proceed to |
| NG |
A |
| OK (w/o Regulator) |
B |
| OK (w/ Regulator) |
C |
|
|
||||
|
|
||||
| A | ||
| ||