Security Indicator Light Circuit
Circuit diagnosis · Vehicles built from Jun 2011
DESCRIPTION
When the theft deterrent system is in the disarmed state, the security indicator light assembly will flash continuously if the engine immobiliser system is set, or not illuminate if the engine immobiliser system is not set*.When the theft deterrent system is in the armed state, the engine immobiliser system is automatically set and the security indicator light assembly will flash continuously*.
When the theft deterrent system is in the arming preparation state or alarm sounding state, the theft warning ECU assembly causes the security indicator light assembly to illuminate.
- *: w/ Engine Immobiliser System
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT SECURITY INDICATOR LIGHT ASSEMBLY |
![]() ![]() |
Remove the security indicator light assembly.
Apply battery voltage between the terminals of the indicator, and check the illumination of the security indicator.
- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Illuminates
- NOTICE:
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator will not illuminate.
- If the voltage is too low, the security indicator light assembly will not illuminate.
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator will not illuminate.
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - THEFT WARNING ECU AND BODY GROUND) |
Disconnect the S10 security indicator light assembly connector.
Disconnect the T36*1 or T39 *2 theft warning ECU assembly connector.
- *1: except 2 Step Unlock Function
- *2: for 2 Step Unlock Function
- *1: except 2 Step Unlock Function
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
- except 2 Step Unlock Function:
Tester Connection
Condition
Specified Condition
S10-2 - T36-27 (IND)
Always
Below 1 Ω
S10-2 or T36-27 (IND) - Body ground
Always
10 kΩ or higher
S10-1 - Body ground
Always
Below 1 Ω
- for 2 Step Unlock Function:
Tester Connection
Condition
Specified Condition
S10-2 - T39-22 (IND)
Always
Below 1 Ω
S10-2 or T39-22 (IND) - Body ground
Always
10 kΩ or higher
S10-1 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | ||
| ||