Home › Engine / Hybrid System › 2TR-FE ENGINE CONTROL › ECM › 2012.04–2012.10
RM1840EF _51 Engine / Hybrid System _009569 2TR-FE ENGINE CONTROL _0052080 ECM A

2TR-FE ENGINE CONTROL  ECM  INSTALLATION  


PROCEDURE

Hide 1.INSTALL NO. 2 ECM BRACKET

a.

Install the No. 2 ECM bracket with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


Hide 2.INSTALL NO. 1 ECM BRACKET

a.

Install the No. 1 ECM bracket with the 2 screws.

Torque:
3.0 N*m (31 kgf*cm, 27 in.*lbf)


Hide 3.INSTALL ECM

a.

Install the ECM with the bolt and 2 nuts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


b.

Connect the 4 connectors.


Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).