Home › Engine / Hybrid System › 1KD-FTV ENGINE CONTROL › MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ Glow Plug Controller) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009570 1KD-FTV ENGINE CONTROL _0052108 MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ Glow Plug Controller) G

1KD-FTV ENGINE CONTROL  MANIFOLD ABSOLUTE PRESSURE SENSOR(w/ Glow Plug Controller)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR

a.

Inspect the power source voltage.

i.

Disconnect the manifold absolute pressure sensor connector.


ii.
A301320
1.375,0.927 1.5,0.927 1.5,0.927 1.677,1.073 false 2.052,1.125 2.208,1.229 2.208,1.229 2.313,1.229 false 0.073,0.042 0.385,0.24 0.313,0.198 10 *a 0.969,0.854 1.438,1.052 0.469,0.198 10 1 E (-) 2.354,1.156 3.042,1.375 0.688,0.219 10 3 VC (+)
*a Front view of wire harness connector
(to Manifold Absolute Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
3 (VC) - 1 (E) Ignition switch ON 4.75 to 5.25 V


If the result is not as specified, inspect the wire harness or ECM (for i-ART: See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for i-ART)>TERMINALS OF ECM, for DPF: See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM(for DPF)>TERMINALS OF ECM).


iii.

Connect the manifold absolute pressure sensor connector.



b.

Check the power supply.

i.

Turn the ignition switch to ON.


ii.

Disconnect the vacuum hose from the manifold absolute pressure sensor.


iii.
A272523
1.729,0.469 2.219,0.698 0.49,0.229 1.729,0.198 2.219,0.427 0.49,0.229 1.896,1.146 2.01,1.792 2.01,1.792 2.01,1.875 false 2.031,1.219 2.906,1.792 2.906,1.792 2.906,1.875 false 1.844,1.135 1.438,0.531 1.438,0.531 1.354,0.531 false 1.844,1.177 1.438,1.771 1.438,1.771 1.354,1.771 false 1.729,1.917 2.469,2.115 0.74,0.198 10 false 5 (PIM)*B 0.135,0.083 0.469,0.24 0.333,0.156 10 false *a 2.646,1.917 3.354,2.094 0.708,0.177 10 false 14 (E2)*B 0.646,0.448 1.479,0.625 0.833,0.177 10 false 6 (EPIM)*A 0.656,1.698 1.375,1.875 0.719,0.177 10 false 12 (PIM)*A 1.813,0.51 2.24,0.656 0.427,0.146 10 false C114 2.25,0.5 2.542,0.656 0.292,0.156 10 false *B 1.813,0.229 2.24,0.375 0.427,0.146 10 false C167 2.25,0.229 2.521,0.375 0.271,0.146 10 false *A
*A for i-ART
*B for DPF
*a Component without harness connected
(ECM)
V100135

Vacuum


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
C167-12 (PIM) - C167-6 (EPIM)*A
C114-5 (PIM) - C114-14 (E2)*B
-13.3 kPa (100 mmHg, 3.94 in.Hg) 0.0 to 0.3 V
-26.6 kPa (199 mmHg, 7.85 in.Hg) 0.1 to 0.4 V
-40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.6 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.


iv.
A272524
1.729,0.531 2.219,0.76 0.49,0.229 1.729,0.26 2.219,0.49 0.49,0.229 1.896,1.208 2.01,1.854 2.01,1.854 2.01,1.938 false 2.031,1.281 2.906,1.854 2.906,1.854 2.906,1.938 false 1.844,1.208 1.438,0.594 1.438,0.594 1.354,0.594 false 1.844,1.25 1.438,1.833 1.438,1.833 1.354,1.833 false 2.365,3.542 2.74,2.875 2.74,2.875 2.854,2.875 false 1.729,1.979 2.385,2.167 0.656,0.188 10 false 5 (PIM)*B 0.135,0.146 0.323,0.313 0.188,0.167 10 false *a 2.646,1.979 3.281,2.156 0.635,0.177 10 false 14 (E2)*B 0.646,0.521 1.479,0.719 0.833,0.198 10 false 6 (EPIM)*A 0.667,1.75 1.385,1.927 0.719,0.177 10 false 12 (PIM)*A 1.823,0.573 2.188,0.719 0.365,0.146 10 false C114 2.25,0.563 2.573,0.74 0.323,0.177 10 false *B 1.802,0.313 2.167,0.458 0.365,0.146 10 false C167 2.25,0.292 2.542,0.448 0.292,0.156 10 false *A 0.135,0.146 0.438,0.323 0.302,0.177 10 false *a 2.906,2.813 3.219,2.979 0.313,0.167 10 false SST
*A for i-ART
*B for DPF
*a Component without harness connected
(ECM)
V100135

Pressure


Using SST, measure the voltage according to the value(s) in the table below.

SST
09992-00242  

Standard Voltage:
Tester Connection Condition Specified Condition
C167-12 (PIM) - C167-6 (EPIM)*A
C114-5 (PIM) - C114-14 (E2)*B
19.6 kPa (0.20 kgf/cm2, 2.84 psi) 0.1 to 0.4 V
39.2 kPa (0.40 kgf/cm2, 5.69 psi) 0.3 to 0.6 V
58.8 kPa (0.60 kgf/cm2, 8.53 psi) 0.5 to 0.8 V
78.5 kPa (0.80 kgf/cm2, 11.4 psi) 0.7 to 1.1 V
98.0 kPa (1.00 kgf/cm2, 14.2 psi) 0.9 to 1.3 V


HINT:

The values in the "Condition" column are gauge pressures.


If the result is not as specified, replace the manifold absolute pressure sensor.