RM1840EF _52 Drivetrain _009618 AXLE AND DIFFERENTIAL _0052566 AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR A

AXLE AND DIFFERENTIAL  AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR  INSTALLATION  


PROCEDURE

Hide 1.INSTALL DIFFERENTIAL VACUUM ACTUATOR ASSEMBLY

a.
C237514

Remove any seal packing material from the contact surface of the differential and clutch case.

NOTICE:

Do not drop oil on the contact surfaces.



b.

Clean residual seal packing material from the contact surfaces using gasoline or alcohol.


c.

Apply seal packing to the differential tube as shown.

Seal packing:

Toyota Genuine seal packing 1281, Three Bond 1281 or equivalent


HINT:

Install the actuator within 3 minutes after applying seal packing.



d.
C237513

Clean the threads of the 4 bolts and retainer bolt holes with toluene or trichloroethylene.


e.

Install the actuator to the differential tube.


f.

Install the 4 bolts.

Torque:
21 N*m (210 kgf*cm, 15 ft.*lbf)


g.

Connect the actuator hose and connector.


h.

Support the front differential with a jack.


i.

Install the 2 front mounting bolts and 2 nuts.

Torque:
137 N*m (1400 kgf*cm, 101 ft.*lbf)


j.

Install the front No. 1 differential mounting nut.

Torque:
87 N*m (887 kgf*cm, 64 ft.*lbf)


k.

Install the front differential breather tube bracket with the bolt.

Torque:
13 N*m (133 kgf*cm, 10 ft.*lbf)


l.

Lower the jack.