Home › Power Source / Network › 1GR-FE BATTERY / CHARGING › GENERATOR › from 2012.10
RM1840EF _57 Power Source / Network _009638 1GR-FE BATTERY / CHARGING _0052675 GENERATOR A

1GR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 5.REMOVE GENERATOR ASSEMBLY

A194920

a.

Disconnect the terminal cap.


b.

Disconnect the generator connector.


c.

Remove the 2 bolts and nut, and then disconnect the generator wire.


d.

Remove the 2 bolts and generator.