HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DIAGNOSTIC TROUBLE CODE CHART  


Air Conditioning System
DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note Link
11 Room Temperature Sensor Circuit An open or short in the room temperature sensor circuit.
·

Cooler thermistor

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(8.5 min. or more)
If the room temperature is approximately -18.6°C (1.48°F) or lower, DTC 11 may be output even though the system is normal. even though the system is normal. Click here
12 Ambient Temperature Sensor Circuit An open or short in ambient temperature sensor circuit
·

Thermistor assembly

·

Accessory meter assembly

·

Air conditioning amplifier assembly

·

Harness or connector


- - Click here
13 Evaporator Temperature Sensor Circuit An open or short in evaporator temperature sensor circuit
·

No. 1 cooler thermistor

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(8.5 min. or more)
- Click here
14 Engine Coolant Temperature Communication Circuit An open or short in engine coolant temperature communication circuit
·

ECD system (for 1KD-FTV [w/ EGR Cooler])

·

ECD system (for 1KD-FTV [w/o EGR Cooler])

·

SFI system (for 2TR-FBE)

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(8.5 min. or more)
- Click here
21 Solar Sensor Circuit An open in cooler thermistor (solar sensor) circuit
(If check is performed in a dark place, DTC 21 may be stored)
·

Cooler thermistor (solar sensor)

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized
(8.5 min. or more)
(Only when circuit is shorted)
- Click here
23 Pressure Switch Circuit When either condition below is met:
·

An open in air conditioner pressure sensor circuit

·

Abnormal refrigerant pressure:

0.196 MPa (2.0 kgf/cm2, 28 psi) or less

3.14 MPa (32.0 kgf/cm2, 455 psi) or high



·

Air conditioner tube & accessory assembly (air conditioner pressure sensor)

·

Refrigerant and refrigerant pipe line

·

Air conditioning amplifier assembly

·

Harness or connector


- - Click here
41 Front Air Mix Damper Control Servo Motor Circuit The air mix control damper position does not change when the air conditioning amplifier assembly operates the air mix damper servo sub-assembly.
·

Air mix damper servo sub-assembly

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(30 sec. or more)
- Click here
42 Air Inlet Damper Control Servo Motor Circuit The air inlet control damper position does not change when the air conditioning amplifier assembly operates the recirculation damper servo sub-assembly.
·

Recirculation damper servo sub-assembly

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized
(30 sec. or more)
- Click here
43 Air Outlet Damper Control Servo Motor Circuit The mode damper position does not change when the air conditioning amplifier assembly operates the mode damper servo sub-assembly.
·

Mode damper servo sub-assembly

·

Air conditioning amplifier assembly

·

Harness or connector


Memorized
(30 sec. or more)
- Click here