| 11
|
Room Temperature Sensor Circuit
|
An open or short in the room temperature sensor circuit.
|
·
Air conditioning amplifier assembly
|
Memorized
(8.5 min. or more)
|
If the room temperature is approximately -18.6°C (1.48°F) or lower, DTC 11 may be output even though the system is normal. even though the system is normal.
|
|
| 12
|
Ambient Temperature Sensor Circuit
|
An open or short in ambient temperature sensor circuit
|
·
Air conditioning amplifier assembly
|
-
|
-
|
|
| 13
|
Evaporator Temperature Sensor Circuit
|
An open or short in evaporator temperature sensor circuit
|
·
Air conditioning amplifier assembly
|
Memorized
(8.5 min. or more)
|
-
|
|
| 14
|
Engine Coolant Temperature Communication Circuit
|
An open or short in engine coolant temperature communication circuit
|
·
ECD system (for 1KD-FTV [w/ EGR Cooler])
·
ECD system (for 1KD-FTV [w/o EGR Cooler])
·
Air conditioning amplifier assembly
|
Memorized
(8.5 min. or more)
|
-
|
|
| 21
|
Solar Sensor Circuit
|
An open in cooler thermistor (solar sensor) circuit
(If check is performed in a dark place, DTC 21 may be stored)
|
·
Cooler thermistor (solar sensor)
·
Air conditioning amplifier assembly
|
Memorized
(8.5 min. or more)
(Only when circuit is shorted)
|
-
|
|
| 23
|
Pressure Switch Circuit
|
When either condition below is met:
·
An open in air conditioner pressure sensor circuit
·
Abnormal refrigerant pressure:
0.196 MPa (2.0 kgf/cm2, 28 psi) or less
3.14 MPa (32.0 kgf/cm2, 455 psi) or high
|
·
Air conditioner tube & accessory assembly (air conditioner pressure sensor)
·
Refrigerant and refrigerant pipe line
·
Air conditioning amplifier assembly
|
-
|
-
|
|
| 41
|
Front Air Mix Damper Control Servo Motor Circuit
|
The air mix control damper position does not change when the air conditioning amplifier assembly operates the air mix damper servo sub-assembly.
|
·
Air mix damper servo sub-assembly
·
Air conditioning amplifier assembly
|
Memorized
(30 sec. or more)
|
-
|
|
| 42
|
Air Inlet Damper Control Servo Motor Circuit
|
The air inlet control damper position does not change when the air conditioning amplifier assembly operates the recirculation damper servo sub-assembly.
|
·
Recirculation damper servo sub-assembly
·
Air conditioning amplifier assembly
|
Memorized
(30 sec. or more)
|
-
|
|
| 43
|
Air Outlet Damper Control Servo Motor Circuit
|
The mode damper position does not change when the air conditioning amplifier assembly operates the mode damper servo sub-assembly.
|
·
Mode damper servo sub-assembly
·
Air conditioning amplifier assembly
|
Memorized
(30 sec. or more)
|
-
|
|