Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM › 2012.04–2012.10
RM1840EF _58 Vehicle Interior _009643 METER / GAUGE / DISPLAY _0052702 METER / GAUGE SYSTEM J

METER / GAUGE / DISPLAY  METER / GAUGE SYSTEM  Auxiliary Fuel Tank Warning Light Circuit  


DESCRIPTION

When fuel with a high percentage of alcohol is used, cold startability will decline because alcohol is difficult to vaporize at low temperatures such as 20°C (68°F) or less. In order to enhance cold startability, a sub-injection system, which consists of the auxiliary fuel tank with a capacity of 600 cc, sub-pump, and solenoid valve, is used on these vehicles.

The meter CPU determines the fuel level in the auxiliary fuel tank using a thermistor that is located in the auxiliary fuel tank.

The thermistor is installed at a height that corresponds to 100 cc (6.1 cu.in.) of fuel remaining in the tank. The cup that the thermistor is mounted in has holes to allow the fuel to enter and leave the area around the thermistor. As a result, the location of the thermistor is maintained in relation to the actual fuel level.

The meter CPU supplies battery voltage to the thermistor. The resistance of the thermistor in the auxiliary fuel tank depends on whether the thermistor is immersed in fuel. When the thermistor is not immersed in fuel, the resistance value decreases as the thermistor generates heat.

The meter CPU detects the voltage between G20-12 (L) and G20-13 (IND). When the voltage between G20-12 (L) and G20-13 (IND) is below 6.5 V, the meter CPU illuminates the auxiliary fuel tank warning light.

NOTICE:

When the temperature inside the auxiliary fuel tank is not between -10°C and 80°C (14°F and 176°F), the auxiliary fuel tank warning light may not operate normally. As a result, the combination meter will only operate the auxiliary fuel tank warning light within 400 seconds after the ignition switch is turned ON.


HINT:
·

This circuit is only for Flexible Fuel Vehicles (FFV).

·

The auxiliary fuel tank may be unnecessary in a warm climate because its purpose is to enhance cold startability. As a result, some drivers may not wish to make use of the auxiliary fuel tank. Therefore, it is possible for the driver to disable the auxiliary fuel tank warning light. Due to the possibility of the warning having been disabled, check the auxiliary fuel tank warning light setting before inspecting this circuit (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>CUSTOMIZE PARAMETERS).

·

A bulb check is not performed for the auxiliary fuel tank warning light.

·

When the fuel level in the auxiliary fuel tank falls below 100 cc (6.1 cu.in.), the auxiliary fuel tank warning light comes on.

·

The auxiliary fuel tank must be replaced if the thermistor malfunctions. The thermistor is not available separately.



WIRING DIAGRAM

E235872
2.323,0.833 2.5,1.052 0.177,0.219 10 false S 2.323,1.219 2.479,1.427 0.156,0.208 10 false E 2.531,0.74 2.635,0.885 0.104,0.146 10 false 1 2.542,1.115 2.667,1.26 0.125,0.146 10 false 2 5.25,0.719 5.438,0.875 0.188,0.156 10 false 12 5.25,1.115 5.448,1.26 0.198,0.146 10 false 13 5.542,0.833 5.844,1.073 0.302,0.24 10 false L 5.542,1.208 5.927,1.448 0.385,0.24 10 false IND 5,1.885 5.385,2.115 0.385,0.229 10 false G20 5,2.052 6.979,2.438 1.979,0.385 10 false Combination Meter Assembly 0.969,1.521 1.271,1.677 0.302,0.156 10 false A72 1.396,2.125 2.719,2.375 1.323,0.25 10 false Auxiliary Fuel Tank 0.969,1.688 3.135,1.958 2.167,0.271 10 false Fuel Suction Plate Sub-assembly

CAUTION / NOTICE / HINT

HINT:

Check the auxiliary fuel tank warning light setting (See pageVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>CUSTOMIZE PARAMETERS).


PROCEDURE

1.CHECK COMBINATION METER ASSEMBLY (OUTPUT VOLTAGE)
a.
E235873
0.458,0.948 0.917,1.229 0.458,0.281 1.51,1.229 0.813,1.594 true 0.563,1.01 0.833,1.177 0.271,0.167 10 false A72 0.646,1.521 0.781,1.698 0.135,0.177 10 false S 0.063,0.052 0.24,0.229 0.177,0.177 10 false *a
*a Front view of wire harness connector
(to Auxiliary Fuel Tank)


Disconnect the A72 fuel suction plate sub-assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A72-1 (S) - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY)

NG

4.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY)
a.

Disconnect the G20 combination meter assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G20-13 (IND) - A72-2 (E) Always Below 1 Ω
G20-13 (IND) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT FUEL SUCTION PLATE SUB-ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT FUEL SUCTION PLATE SUB-ASSEMBLY
a.
E233173
1.719,0.417 2.208,0.708 0.49,0.292 1.365,1.292 1.042,0.552 true 1.469,1.292 2.49,0.542 true 1.833,0.49 2.125,0.667 0.292,0.177 10 false G20 0.781,0.448 1.083,0.604 0.302,0.156 10 false IND 2.552,0.406 2.677,0.615 0.125,0.208 10 false L 0.063,0.042 0.271,0.229 0.208,0.188 10 false *a
*a Component with harness connected
(Combination Meter Assembly)


Reconnect the A72 fuel suction plate sub-assembly and G20 combination meter assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G20-12 (L) - G20-13 (IND) Ignition switch ON, auxiliary tank is empty (Auxiliary tank warning light comes on) Below 6.5 V
G20-12 (L) - G20-13 (IND) Ignition switch ON, auxiliary tank is full (Auxiliary tank warning light goes off) 6.6 V or higher


HINT:

If the result is not as specified, the whole fuel suction plate sub-assembly should be replaced if the thermistor has a malfunction because this part is not independently supplied.



Result:
Proceed to
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

4.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - FUEL SUCTION PLATE SUB-ASSEMBLY)
a.

Disconnect the G20 combination meter assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
G20-12 (L) - A72-1 (S) Always Below 1 Ω
G20-12 (L) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR