DTC P0443 Evaporative Emission Control System Purge Control Valve Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0443 | The terminal voltage of the ECM output circuit does not correspond with the drive signals from the ECM to the purge VSV (1-trip detection logic). |
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VSV FOR EVAP CONTROL) |
![]() |
Connect the intelligent tester to the DLC3.
Disconnect the vacuum hose of the charcoal canister from the purge VSV.
Start the engine.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Evap Control.
When the purge VSV is operated using the intelligent tester, check whether the purge VSV applies suction to your finger.
| Tester Operation | Specified Condition |
| VSV is ON | Suction applied |
| VSV is OFF | No suction applied |
Reconnect the vacuum hose of the charcoal canister to the purge VSV.
|
| ||||
| OK | ||
| ||
| 2.INSPECT PURGE VSV |
Inspect the purge VSV (Click here).
|
| ||||
| OK | |
| 3.INSPECT PURGE VSV (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the purge VSV connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| V3-2 - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Purge VSV) |
Reconnect the purge VSV connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM) |
Disconnect the purge VSV connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| V3-1 - E22-19 (PRG) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| V3-1 or E22-19 (PRG) - Body ground | Always | 10 kΩ or higher |
Reconnect the purge VSV connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (PURGE VSV - INTEGRATION RELAY [MAIN RELAY]) |
Disconnect the purge VSV connector.
Remove the integration relay (MAIN relay) from the engine room relay block and disconnect the integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| V3-2 - 1J-5 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| V3-2 or 1J-5 - Body ground | Always | 10 kΩ or higher |
Reconnect the integration relay connector.
Reinstall the integration relay.
Reconnect the purge VSV connector.
|
| ||||
| OK | ||
| ||