C1241
| One of the following conditions is met:
- At a vehicle speed of 3 km/h (2 mph) or more, the IG1 terminal voltage is below 9.5 V for 10 seconds or more.
- When the solenoid relay remains on and the IG1 terminal voltage is below 9.5 V, the relay contact is open for 0.22 seconds or more.
- With the IG1 terminal voltage at 9.5 V or less, the vehicle speed sensor power supply decreases for 60 seconds or more.
- When the motor relay and fail-safe relay are on, the voltage at terminal IG1 is below 9.5 V and the actuator pump motor is off for 0.2 seconds or more.
| - ECU-IG NO. 2 fuse
- Battery
- Charging system
- Power source circuit
- Internal power supply circuit of skid control ECU (Brake actuator assembly)
|