DTC 42 Air Inlet Damper Control Servo Motor Circuit |
| DTC Code | Detection Item | Trouble Area |
| 42 | The air inlet control damper position does not change when the air conditioning amplifier assembly operates the recirculation damper servo sub-assembly. |
|

| 1.CHECK HARNESS AND CONNECTOR (RECIRCULATION DAMPER SERVO - AIR CONDITIONING AMPLIFIER) |
Disconnect the D1 recirculation damper servo sub-assembly connector.
Disconnect the A44 and A43 air conditioning amplifier assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D1-5 - A44-22 (AIR) | Always | Below 1 Ω |
| D1-4 - A44-23 (AIF) | ||
| D1-2 - A43-17 (PIA) | ||
| D1-3 - A43-16 (AGND) | ||
| D1-1 - A43-21 (AUXO) | ||
| D1-5 - Body ground | Always | 10 kΩ or higher |
| D1-4 - Body ground | ||
| D1-2 - Body ground | ||
| D1-3 - Body ground | ||
| D1-1 - Body ground |
|
| ||||
| OK | |
| 2.REPLACE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY |
Temporally replace the recirculation damper servo sub-assembly with a new or normally functioning one (Click here).
Check the air inlet control damper operates normally.
| Result | Proceed to |
| OK | A |
| NG (When troubleshooting according to problem symptoms table.) | B |
| NG (When troubleshooting according to DTC.) | C |
|
| ||||
|
| ||||
| A | ||
| ||