When the heater switch assembly is pushed, the air conditioning amplifier assembly turns on the viscous heater relay and operates the viscous heater. If the viscous heater does not operate when the heater switch assembly is pushed, there may be a problem in the circuit shown below.
When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| IDLE UP/PWR HEAT Switch | Heater switch assembly | ON or OFF | ON: Heater switch assembly on
OFF: Heater switch assembly off |
- |
| Tester Display |
|---|
| IDLE UP/PWR HEAT Switch |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Viscous Heater | Viscous heater relay | ON/OFF | - |
| Tester Display |
|---|
| Viscous Heater |
Viscous heater relay operates.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Heater Switch Assembly) |
Disconnect the heater switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G76-5 (E) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G76-4 (IG) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the heater switch assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>HEATER SWITCH>REMOVAL
Inspect the heater switch assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>HEATER SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G76 heater switch assembly connector
Disconnect the G33 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G76-1 (IN) - G33-4 (SWVC) | Always | Below 1 Ω |
| G76-1 (IN) or G33-4 (SWVC) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the viscous heater relay (VISCOUS) from the No. 5 instrument panel relay block.
Inspect the viscous heater relay (VISCOUS).
Click hereVehicle Interior>HEATING / AIR CONDITIONING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the air conditioning amplifier assembly connector.
| *a | Rear view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G33-19 (MG+) - Body ground | Ignition switch off | Below 1 V |
| G33-19 (MG+) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the compressor assembly with magnet clutch.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>VISCOUS HEATER>REMOVAL
Inspect the compressor assembly with magnet clutch.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>VISCOUS HEATER>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the viscous heater relay (VISCOUS) from the No. 5 instrument panel relay block.
Disconnect the C107 viscous with magnet clutch heater assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - C107-1 (MG+) | Always | Below 1 Ω |
| Relay terminal 3 or C107-1 (MG+) - Body ground | Always | 10 kΩ or higher |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Relay terminal 2 - Body ground | Ignition switch off | Below 1 V |
| Relay terminal 2 - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG