Home › Engine / Hybrid System › 2GD-FTV ENGINE CONTROL › ECD SYSTEM(w/ Urea SCR System) › from 2016.03
RM3250E _51 Engine / Hybrid System _038005 2GD-FTV ENGINE CONTROL _0262511 ECD SYSTEM(w/ Urea SCR System) C

2GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  P203C  Reductant Level Sensor Circuit Low  P203D  Reductant Level Sensor Circuit High  


DESCRIPTION

The urea pump has a level sensor that detects the position of the surface of the fluid inside the urea tank in order to measure the remaining quantity of urea solution.

When the remaining quantity of urea solution falls below a fixed value, a warning is displayed on the combination meter.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P203C Reductant Level Sensor Circuit Low An open or short in the level sensor (urea pump) circuit for 3 seconds or more (1 trip detection logic).
·

Open or short in the level sensor circuit

·

Level sensor (urea pump)

·

Urea pump control ECU


Comes on DTC stored
P203D Reductant Level Sensor Circuit High An open or short in the level sensor (urea pump) circuit for 3 seconds or more (1 trip detection logic).
·

Open or short in the level sensor circuit

·

Level sensor (urea pump)

·

Urea pump control ECU


Comes on DTC stored

Related Data List
DTC No. Data List
P203C
P203D
Reductant Level

CONFIRMATION DRIVING PATTERN

DTC No. DTC Detection Drive Pattern
P203C
P203D
Ignition switch to ON for 3 seconds or more

WIRING DIAGRAM

A357972E03
1.375,0.438 1.99,0.635 0.615,0.198 10 false VLV1 1.479,1.01 1.938,1.208 0.458,0.198 10 false LV1 1.385,1.552 2,1.75 0.615,0.198 10 false ELV1 0.396,2.052 0.708,2.25 0.313,0.198 10 false g6 0.406,2.229 4.073,2.427 3.667,0.198 10 false Level Sensor (Urea Pump) 5.688,0.458 6.302,0.656 0.615,0.198 10 false VCLU 5.708,1.031 6.167,1.229 0.458,0.198 10 false LVU 5.719,1.563 6.177,1.76 0.458,0.198 10 false ELU 5.406,2.031 5.719,2.229 0.313,0.198 10 false g1 5.417,2.219 6.958,2.417 1.542,0.198 10 false Urea Pump Control ECU 1.802,0.573 2.115,0.771 0.313,0.198 10 false 13 1.802,1.135 2.115,1.333 0.313,0.198 10 false 14 1.802,1.677 1.958,1.875 0.156,0.198 10 false 6 5.406,0.573 5.719,0.771 0.313,0.198 10 false 60 5.406,1.146 5.719,1.344 0.313,0.198 10 false 59 5.396,1.688 5.708,1.885 0.313,0.198 10 false 58

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.INSPECT LEVEL SENSOR (UREA PUMP)
a.

Inspect the level sensor (urea pump).

Click hereEngine / Hybrid System>2GD-FTV EMISSION CONTROL>UREA PUMP>INSPECTION


Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (LEVEL SENSOR - UREA PUMP CONTROL ECU)

NG

7.REPLACE UREA PUMP
2.CHECK HARNESS AND CONNECTOR (LEVEL SENSOR - UREA PUMP CONTROL ECU)
A360342C13
1.594,0.125 2.021,0.354 0.427,0.229 5.302,0.115 5.729,0.344 0.427,0.229 1.146,1.458 1.615,0.802 true 5.615,1.5 5.865,1.167 true 5.948,1.146 6.417,1.479 true 1.719,1.438 1.646,0.948 true 1.781,0.948 2.406,1.448 true 4.823,1.542 5.792,1.156 true 0.167,0.135 0.479,0.292 0.313,0.156 10 false *a 4.229,0.156 4.542,0.313 0.313,0.156 10 false *b 1.729,0.167 2.042,0.365 0.313,0.198 10 false g6 5.427,0.156 5.74,0.354 0.313,0.198 10 false g1 0.917,1.479 1.375,1.677 0.458,0.198 10 false ELV1 2.344,1.479 2.802,1.677 0.458,0.198 10 false VLV1 4.375,1.552 5.604,1.75 1.229,0.198 10 false 58 (ELU) 6.24,1.51 7.156,1.708 0.917,0.198 10 false 60 (VCLU) 1.635,1.469 2.094,1.667 0.458,0.198 10 false LV1 5.365,1.521 6.438,1.719 1.073,0.198 10 false 59 (LVU)
*a Front view of wire harness connector
(to Urea Pump)
*b Front view of wire harness connector
(to Urea Pump Control ECU)


a.

Disconnect the urea pump connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
g6-13 (VLV1) - g1-60 (VCLU) Always Below 1 Ω
g6-14 (LV1) - g1-59 (LVU) Always Below 1 Ω
g6-6 (ELV1) - g1-58 (ELU) Always Below 1 Ω
g6-13 (VLV1) or g1-60 (VCLU) - Body ground and other terminals Always 10 kΩ or higher
g6-14 (LV1) or g1-59 (LVU) - Body ground and other terminals Always 10 kΩ or higher
g6-6 (ELV1) or g1-58 (ELU) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.CHECK DTC OUTPUT

NG

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
3.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON and turn the GTS on.


c.

Clear the DTCs.


d.

Turn the ignition switch off and wait for at least 30 seconds.


e.

Turn the ignition switch to ON and wait for 3 seconds or more.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine / Trouble Codes.

Powertrain > Engine > Trouble Codes
50001 234

h.

Read the DTCs.


Result:
Result Proceed to
DTC P203C or P203D is output A
No DTC is output B



A

4.REPLACE UREA PUMP CONTROL ECU

B

END

4.REPLACE UREA PUMP CONTROL ECU

Result:
Proceed to
NEXT



NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON and turn the GTS on.


c.

Clear the DTCs.


d.

Turn the ignition switch off and wait for at least 30 seconds.


e.

Turn the ignition switch to ON and wait for 3 seconds or more.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine / Trouble Codes.


h.

Confirm that the DTC is not output again.

Powertrain > Engine > Trouble Codes
50001 234

Result:
Proceed to
NEXT



NEXT

END

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace harness or connector.


Result:
Proceed to
NEXT



NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
7.REPLACE UREA PUMP

Result:
Proceed to
NEXT



NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED