Home › Engine / Hybrid System › 2GD-FTV EMISSION CONTROL › UREA TANK › from 2016.03
RM3250E _51 Engine / Hybrid System _038008 2GD-FTV EMISSION CONTROL _0262571 UREA TANK A

2GD-FTV EMISSION CONTROL  UREA TANK  INSTALLATION  


PROCEDURE

Hide 1.INSTALL UREA TANK HARNESS

a.

Install the urea tank harness to the urea tank sub-assembly.


Hide 77862A 2.INSTALL NO. 2 UREA TANK BRACKET

a.

Install the No. 2 urea tank bracket to the urea tank sub-assembly with the bolt.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


Hide 51568 3.INSTALL PROPELLER SHAFT GUARD BRACKET (for 4WD)

a.

Install the propeller shaft guard bracket to the urea tank sub-assembly with the bolt.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


Hide 77861A 4.INSTALL NO. 1 UREA TANK BRACKET (for Pre-Runner)

a.

Install the No. 1 urea tank bracket to the urea tank sub-assembly with the bolt.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


Hide 6.INSTALL NO. 2 UREA TANK BREATHER TUBE

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the No. 2 urea tank breather tube connector before connection. Clean if necessary.


a.

Install the No. 2 urea tank breather tube to the urea tank sub-assembly.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the No. 2 urea tank breather tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the No. 2 urea tank breather tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).


iii.
A379871C01
1.417,0.615 1.635,0.229 1.635,0.229 1.781,0.229 true 1.802,0.125 2.052,0.302 0.25,0.177 10 false *a
*a Retainer
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the urea tank sub-assembly. Push the No. 2 urea tank breather tube connector into the urea tank sub-assembly until the No. 2 urea tank breather tube connector makes a "click" sound.


iv.

Push down the retainer.


v.

After connecting the urea tank sub-assembly and the No. 2 urea tank breather tube connector, check that the urea tank sub-assembly and No. 2 urea tank breather tube connector are securely connected by trying to pull them apart.



Hide 77801A 8.INSTALL UREA TANK SUB-ASSEMBLY

a.
A379855C02
1.396,2.021 1.615,2.198 0.219,0.177 10 true *A 2.417,2.01 2.635,2.188 0.219,0.177 10 true *B 0.344,3.104 0.51,3.271 0.167,0.167 10 true A 0.938,3.104 1.104,3.271 0.167,0.167 10 true A 1.521,3.031 1.688,3.198 0.167,0.167 10 true A 2.156,2.948 2.323,3.115 0.167,0.167 10 true A 2.573,3.042 2.74,3.208 0.167,0.167 10 true B 3.188,2.979 3.354,3.146 0.167,0.167 10 true B
*A for Pre-Runner
*B for 4WD


Install the urea tank sub-assembly to the body with the 4 bolts.

Torque:
for bolt A : 14.3 N*m (146 kgf*cm, 11 ft.*lbf)
for bolt B : 30 N*m (306 kgf*cm, 22 ft.*lbf)


b.

Connect the urea tank sub-assembly to the No. 3 crossmember sub-assembly with the bolt.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


c.

Connect the urea tank sub-assembly to the No. 3 urea tank bracket with the bolt.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)


d.

Attach the 2 clamps and connect the 3 connectors to the urea tank harness.


Hide 77910 9.CONNECT UREA TANK FILLER PIPE ASSEMBLY

NOTICE:

Check for dirt or mud on the urea tank filler pipe assembly and around the urea tube connector before connection. Clean if necessary.


a.

Connect the urea tank filler tube to the urea tank sub-assembly.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the urea tank filler tube and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tank filler tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).


iii.
A379862C01
1.958,0.917 2.229,0.375 2.229,0.375 2.448,0.375 true 2.469,0.271 2.698,0.448 0.229,0.177 10 true *a
*a Retainer
V100135

Push
V100136

Push Down


Align the axis of the urea tank filler tube connector with the axis of the urea tank sub-assembly. Push the urea tank filler tube connector into the urea tank sub-assembly until the urea tank filler tube connector makes a "click" sound.


iv.

Push down the retainer.


v.

After connecting the urea tank sub-assembly and the urea tank filler tube connector, check that the urea tank sub-assembly and urea tank filler tube connector are securely connected by trying to pull them apart.



b.

Connect the No. 1 urea tank breather tube to the No. 2 urea tank breather tube.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the No. 2 urea tank breather tube and No. 1 urea tank breather tube, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the No. 1 urea tank breather tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the No. 2 urea tank breather tube with water to remove all solidified urea solution (white solids).


iii.
A379861C01
1.781,0.917 2.198,0.448 2.198,0.448 2.354,0.448 true 2.385,0.344 2.594,0.542 0.208,0.198 10 true *a
*a Retainer
V100135

Push
V100136

Push Down


Align the axis of the No. 1 urea tank breather tube connector with the axis of the No. 2 urea tank breather tube. Push the No. 1 urea tank breather tube connector into the No. 2 urea tank breather tube until the No. 1 urea tank breather tube connector makes a "click" sound.


iv.

Push down the retainer.


v.

After connecting the No. 2 urea tank breather tube and the No. 1 urea tank breather tube connector, check that the No. 2 urea tank breather tube and No. 1 urea tank breather tube connector are securely connected by trying to pull them apart.



c.

Install the pipe clamp to the urea tank filler pipe assembly.


Hide 10.CONNECT NO. 1 UREA TUBE WITH HEATER

NOTICE:

Check for dirt or mud on the urea tube with heater assembly and around the urea tube connector before connection. Clean if necessary.


a.

Connect the No. 1 urea tube with heater to the urea tube with heater assembly.

HINT:

If there is any solidified urea solution (white solids) on the connection areas of the No. 1 urea tube with heater and urea tube with heater assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.


i.

Wash the connection area of the urea tube connector with water to remove all solidified urea solution (white solids).


ii.

Wipe off the connection area of the urea tube with heater assembly with water to remove all solidified urea solution (white solids).


iii.
A379854C01
0,0 0,0 false
V100135

Push
V100136

Push Down


Align the axis of the urea tube connector with the axis of the urea tube with heater assembly. Push the urea tube connector into the urea tube with heater assembly until the urea tube connector makes a "click" sound.


iv.

After connecting the urea tube with heater assembly and the urea tube connector, check that the urea tube with heater assembly and urea tube connector are securely connected by trying to pull them apart.


v.

Attach the lock claws to the urea tube connector by pushing down on the cover.


vi.

Attach the No. 1 urea tube with heater to the tube clamp.


vii.

Attach the connector to the tube clamp.


viii.

Connect the connector to the urea tube with heater assembly.



Hide 77851A 11.INSTALL UREA TANK PROTECTOR

a.

Install the urea tank protector to the body with the 3 bolts.

Torque:
14.3 N*m (146 kgf*cm, 11 ft.*lbf)