The theft body ECU receives a door open or closed signal from front door courtesy light switch and combination meter assembly.
If the body ECU has been replaced, it is necessary to initialize the body ECU.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
Check the meter / gauge system (door courtesy switch) is functioning normally.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
| Result |
|---|
| OK |
| NG |
OK
NG
Remove the body ECU.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Connect the instrument panel junction block assembly connector.
Disconnect the G9 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-18 (DCTY) - Body ground | Driver side door closed (OFF) → open (ON) | 10 kΩ or higher → Below 1 Ω |
| G33-14 (PCTY) - Body ground | Front passenger side door closed (OFF) → open (ON) | 10 kΩ or higher → Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG (for Driver Side) |
| NG (for Passenger Side) |
OK
NG (for Driver Side)
NG (for Passenger Side)
| *a | Component with harness connected
(Instrument Panel Junction Block Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2Q-2 - Body ground | All doors closed → any door open | 11 to 14 V → Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>THEFT DETERRENT SYSTEM>PROBLEM SYMPTOMS TABLE
NG
Remove the body ECU.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Connect the instrument panel junction block assembly connectors.
Disconnect the G9 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G9-12 (DOOR) - A-21 (ACTY) | Always | Below 1 Ω |
| G9-12 (DOOR) - Body ground | Always | 10 kΩ or higher |
| Result |
|---|
| OK |
| NG |
OK
NG
Disconnect the combination meter assembly connector.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G9-12 (DOOR) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 2Q instrument panel junction block assembly connector.
Disconnect the G9 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G9-12 (DOOR) - 2Q-2 | Always | Below 1 Ω |
| G9-12 (DOOR) - Body ground | Always | 10 kΩ or higher |
| Result |
|---|
| OK |
| NG |
OK
NG