The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.
Refer to DTC P0200 (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>P0200).
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>REGISTRATION) and initialization (See page Engine / Hybrid System>1KD-FTV ENGINE CONTROL>ECD SYSTEM>INITIALIZATION).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
Disconnect the injector driver connectors.
| *a | Front view of wire harness connector
(to Injector Driver) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C120-2 (+B) - C120-3 (GND) | Ignition switch ON | 11 to 14 V |
Reconnect the injector driver connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the EDU relay from engine room relay block.
Click hereEngine / Hybrid System>1KD-FTV ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the EDU relay from the engine room relay block and junction block assembly.
Disconnect the injector driver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C120-2 (+B) - EDU relay tarminal 5 | Always | Below 1 Ω |
| C120-3 (GND) - Body ground | Always | Below 1 Ω |
| C120-2 (+B) or EDU relay tarminal 5 - Body ground | Always | 10 kΩ or higher |
Reconnect the injector driver connector.
Reinstall the EDU relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the EDU relay from the engine room relay block and junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G141-10 (IREL) - EDU relay tarminal 2 | Always | Below 1 Ω |
| G141-10 (IREL) or EDU relay tarminal 2 - Bodyground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the EDU relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG