Home › Power Source / Network › 2GD-FTV BATTERY / CHARGING › CHARGING SYSTEM › from 2016.01
RM3270E _57 Power Source / Network _048964 2GD-FTV BATTERY / CHARGING _0239208 CHARGING SYSTEM C

2GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  P161A  Lost Communication with Alternator  


DESCRIPTION

The ECM and generator assembly each detect reception malfunctions. A generator assembly reception malfunction detected by the generator assembly is sent to the ECM via LIN communication. If there is a malfunction in either the ECM or generator assembly, the ECM determines that there is a LIN communication malfunction and outputs a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Memory
P161A Lost Communication with Alternator Diagnosis condition:
·

Engine switch on (IG)


Malfunction status:
·

When the ECM cannot receive LIN communication, the generator assembly cannot receive LIN communication for approximately 17 minutes or more.


Other:
·

1 trip


·

Generator assembly

·

ECM

·

Wire harness or connector


Displayed DTC stored

WIRING DIAGRAM

E221308E17
1.792,0.833 2.25,1.031 0.458,0.198 10 false 2 0.667,1.667 1.125,1.865 0.458,0.198 10 false C8 1.458,1.021 1.917,1.219 0.458,0.198 10 false LIN 0.667,1.833 2,2.083 1.333,0.25 10 false Generator Assembly 5.375,0.833 5.833,1.031 0.458,0.198 10 false 7 5.667,1.031 6.125,1.229 0.458,0.198 10 false LIN 5.833,1.833 6.292,2.031 0.458,0.198 10 false C41 5.833,2 6.292,2.198 0.458,0.198 10 false ECM 0.917,2.354 2.542,2.552 1.625,0.198 10 false : LIN Communication Line

PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)
a.

Disconnect the C41 ECM connector.


b.

Disconnect the C8 generator assembly connector.


c.

Disconnect the A42 battery state sensor assembly connector.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C41-7 (LIN) - C8-2 (LIN) Always Below 1 Ω
C41-7 (LIN) or C8-2 (LIN) - Body ground Engine switch off
(while LIN communication is stopped)
10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT GENERATOR ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT GENERATOR ASSEMBLY
a.

Result:
Result
OK
NG



OK

NG