Home › Brake › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS › REAR SPEED SENSOR
RM1880E _54 Brake _013226 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS _0068561 REAR SPEED SENSOR A

BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  REAR SPEED SENSOR  INSTALLATION  


PROCEDURE

Hide 1.INSTALL SKID CONTROL SENSOR CLAMP

a.

Install the skid control sensor clamp with the bolt.

Torque:
32 N*m (326 kgf*cm, 24 ft.*lbf)

NOTICE:

Make sure the clamp rotation stopper touches the installation position.



Hide 2.INSTALL REAR SPEED SENSOR RH

a.

Install the speed sensor with the bolt.

Torque:
8.5 N*m (87 kgf*cm, 75 in.*lbf)

NOTICE:
·

Make sure there are no pieces of iron or other foreign matter attached to the sensor tip.

·

While inserting the speed sensor into the axle housing hole, do not strike or damage the sensor tip.

·

After installing the speed sensor, make sure there is no clearance or foreign matter between the sensor stay part and the axle housing.




b.

Attach the 6 clamps.

NOTICE:

When attaching the clamps, do not twist the wire harness.



c.

Connect the connector.

NOTICE:
·

Pass the sensor connector between the brake tube and axle housing before connecting it to the wire harness connector on the vehicle.

·

Securely connect the connector.

·

When connecting the connector, do not twist the wire harness.




d.

Attach the connector to the skid control sensor clamp.


Hide 3.INSTALL REAR SPEED SENSOR LH

a.

Install the speed sensor with the bolt.

C189959

Torque:
8.5 N*m (87 kgf*cm, 75 in.*lbf)

NOTICE:
·

Make sure there are no pieces of iron or other foreign matter attached to the sensor tip.

·

While inserting the speed sensor into the axle housing hole, do not strike or damage the sensor tip.

·

After installing the speed sensor, make sure there is no clearance or foreign matter between the sensor stay part and the axle housing.




b.

Attach the 3 clamps.

NOTICE:

When attaching the clamps, do not twist the wire harness.



c.

Connect the connector.

NOTICE:
·

Securely connect the connector.

·

When connecting the connector, do not twist the wire harness.




d.

Attach the connector.


Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).