Home › Vehicle Interior › INTERIOR PANELS / TRIM › UPPER INSTRUMENT PANEL
RM1880E _58 Vehicle Interior _013247 INTERIOR PANELS / TRIM _0068691 UPPER INSTRUMENT PANEL A

INTERIOR PANELS / TRIM  UPPER INSTRUMENT PANEL  REMOVAL  


CAUTION / NOTICE / HINT

HINT:
·

Use the same procedure for RHD and LHD vehicles.

·

The procedure listed below is for LHD vehicles.



PROCEDURE

Hide 1. TABLE OF BOLT, SCREW AND NUT

B279405
0.135,2.792 2.083,3.083 1.948,0.292 10 false mm (in.) (L = Length) 0.281,0.292 0.948,0.583 0.667,0.292 10 false Code 1.76,0.281 2.844,0.583 1.083,0.302 10 false Shape 0.323,2.083 0.833,2.417 0.51,0.333 10 false <B> 0.333,1.073 0.729,1.417 0.396,0.344 10 false <A> 2.302,0.75 2.917,1.042 0.615,0.292 10 false φ = 5 2.302,0.948 3.094,1.219 0.792,0.271 10 false (0.197) 2.302,1.219 3.125,1.469 0.823,0.25 10 false L = 14 2.302,1.396 3.073,1.646 0.771,0.25 10 false (0.551)

a.

All bolts, screws and nuts relevant to installing and removing the instrument panel are shown along with their alphabetical code in the table.


Hide 2. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 3.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:

Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.


NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 4.REMOVE LOWER INSTRUMENT CLUSTER FINISH PANEL

B291270

a.

Detach the 7 claws and remove the lower instrument cluster finish panel.


Hide 5.REMOVE HEADLIGHT DIMMER SWITCH ASSEMBLY

Hide 6.REMOVE NO. 1 INSTRUMENT CLUSTER FINISH PANEL

B291273

a.

Remove the clip <B>.


b.

Detach the 9 claws and remove the No. 1 instrument cluster finish panel.


c.

w/ Light Control Rheostat:

Disconnect the connector.


Hide 8.REMOVE CENTER LOWER INSTRUMENT CLUSTER FINISH PANEL

B279083
2.146,2.573 2.146,1.844 true 2.083,2.625 2.49,2.938 0.406,0.313 10 false *1
*1 Protective Tape


a.

Put protective tape around the center lower instrument cluster finish panel.


b.

Using a moulding remover, detach the 3 claws and 2 clips and remove the center lower instrument cluster finish panel.


Hide 9.REMOVE CENTER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY

B279082

a.

for Manual Air Conditioning System:

i.

Detach the 9 claws.


ii.
B279097

Detach the 4 claws and disconnect the air conditioning control.


iii.

Disconnect the connectors and remove the center instrument cluster finish panel.



b.
B279081

for Automatic Air Conditioning System:

i.

Detach the 9 claws.


ii.

Disconnect the connectors and remove the center instrument cluster finish panel.



Hide 10.REMOVE INSTRUMENT PANEL FINISH PLATE

B291274

a.

Detach the 6 claws and remove the instrument panel finish plate.


Hide 11.REMOVE LOWER FRONT PILLAR GARNISH LH

Hide 12.REMOVE LOWER FRONT PILLAR GARNISH RH

Hide 13.REMOVE FRONT PILLAR GARNISH LH

B279270

a.

Remove the part of the front door opening trim attached to the front pillar garnish.


b.

Detach the 3 clips and remove the front pillar garnish.


Hide 14.REMOVE FRONT PILLAR GARNISH RH

HINT:

Use the same procedure described for the LH side.


Hide 16.REMOVE UPPER INSTRUMENT PANEL SUB-ASSEMBLY

a.

for LHD:

i.

Put protective tape around the upper instrument panel.


ii.

Remove the 4 screws <A>.


iii.

Using a moulding remover, detach the 6 claws and 5 guides and remove the upper instrument panel.


iv.

for Automatic Air Conditioning System:

Disconnect the connector.

B289823
6.042,1.573 6.042,0.979 6.042,0.979 6.302,0.979 true 6.365,0.885 6.656,1.146 0.292,0.26 10 false *1 4.917,2.052 5.281,2.344 0.365,0.292 10 false *2 3.677,1.813 4.021,2.063 0.344,0.25 10 false *2 4.229,1.677 4.427,1.865 0.198,0.188 10 true *2 2.917,1.896 3.104,2.083 0.188,0.188 10 true *2
*1 Protective Tape *2 Screw <A>




b.

for RHD:

i.

Put protective tape around the upper instrument panel.


ii.

Remove the 4 screws <A>.


iii.

Using a moulding remover, detach the 6 claws and 5 guides.


iv.

Disconnect the connector and remove the upper instrument panel.

B279087
6.479,1.542 6.729,1.542 false 6.823,1.469 7.083,1.667 0.26,0.198 10 false *1 2.667,2.271 2.958,2.521 0.292,0.25 10 false *2 3.656,1.76 3.969,1.969 0.313,0.208 10 false *2 4.25,1.844 4.542,2.094 0.292,0.25 10 false *2 5.135,1.563 5.417,1.75 0.281,0.188 10 false *2
*1 Protective Tape *2 Screw <A>