INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT GENERATOR ROTOR ASSEMBLY |
Check the generator rotor for an open circuit.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Slip ring - Slip ring
20°C (68°F)
2.1 to 2.5 Ω
If the result is not as specified, replace the generator rotor assembly.Text in Illustration *1
Slip Ring
Check if the generator rotor is grounded.
Measure the resistance according to the value(s) in the table below.

- Standard Condition:
Tester Connection
Condition
Specified Condition
Slip ring - Rotor core
Always
10 kΩ or higher
If the result is not as specified, replace the generator rotor assembly.Text in Illustration *1
Slip Ring
*2
Rotor Core
Check that the slip rings are not rough or scored.
If they are rough or scored, replace the generator rotor assembly.
Using a vernier caliper, measure the slip ring diameter.

- Standard diameter:
- 14.2 to 14.4 mm (0.559 to 0.567 in.)
- Minimum diameter:
- 14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.Text in Illustration *1
Diameter
Inspect the bearing.
Check that the bearing is not rough or worn.
If necessary, replace the generator rotor assembly.
| INSPECT DRIVE END FRAME |
Check the stator for an open circuit.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Coil lead - Coil lead
Always
Below 1 Ω
If the result is not as specified, replace the generator assembly.Text in Illustration *1
Coil Lead
Check the stator for a short circuit.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Coil lead - Drive end frame
Always
10 kΩ or higher
If the result is not as specified, replace the generator assembly.Text in Illustration *1
Coil Lead
*2
Drive End Frame
Inspect the bearing.
Check that the bearing is not rough or worn.
If necessary, replace the generator assembly.
| INSPECT BRUSH HOLDER |
Using a vernier caliper, measure the exposed brush length.

- Standard exposed length:
- 9.5 to 11.5 mm (0.374 to 0.453 in.)
- Minimum exposed length:
- 4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the brush holder.Text in Illustration *1
Length
| INSPECT GENERATOR HOLDER WITH RECTIFIER |
Check the positive terminal of the rectifier.

Text in Illustration *1
Positive (+) Terminal
*2
Rectifier Terminal
Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator holder with rectifier.
Check the negative terminal of the rectifier.

Text in Illustration *1
Negative (-) Terminal
Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.
If the result is not as specified, replace the generator holder with rectifier.
| INSPECT GENERATOR REGULATOR ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal F - Terminal B
Always
Below 1 Ω or higher than 10 kΩ
If the result is not as specified, replace the generator regulator assembly.Text in Illustration *1
Terminal F
*2
Terminal B
- HINT:
- When the ohmmeter leads are initially touched to the regulator, one of the above values is output. When the leads are reversed, the reading changes to the other value.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal F - Terminal E
Always
Below 1 Ω or higher than 10 kΩ
If the result is not as specified, replace the generator regulator assembly.Text in Illustration *1
Terminal F
*2
Terminal E
- HINT:
- When the ohmmeter leads are initially touched to the regulator, one of the above values is output. When the leads are reversed, the reading changes to the other value.