Hold the center of the generator with clutch pulley and confirm that the outer ring turns counterclockwise and does not turn clockwise.
Text in Illustration
Free
Lock
If the result is not as specified, replace the generator with clutch pulley.
INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
Using a vernier caliper, measure the brush length.
Standard exposed length:
9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length:
4.5 mm (0.177 in.)
Text in Illustration
*1
Length
If the brush length is less than the minimum, replace the generator brush holder assembly.
INSPECT GENERATOR REGULATOR ASSEMBLY
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal F - Terminal B
Always
Below 1 Ω or higher than 10 kΩ
Text in Illustration
*1
Terminal F
*2
Terminal B
If the result is not as specified, replace the generator regulator assembly.
HINT:
When the ohmmeter leads are initially touched to the regulator, one of the above values is output.
When the leads are reversed, the reading changes to the other value.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal F - Terminal E
Always
Below 1 Ω or higher than 10 kΩ
Text in Illustration
*1
Terminal F
*2
Terminal E
If the result is not as specified, replace the generator regulator assembly.
HINT:
When the ohmmeter leads are initially touched to the regulator, one of the above values is output.
When the leads are reversed, the reading changes to the other value.
INSPECT GENERATOR HOLDER WITH RECTIFIER
Inspect the positive (+) rectifier.
Using an ohmmeter, connect one tester probe to the positive (+) terminal and the other to each rectifier terminal.
Text in Illustration
*1
Positive (+) Terminal
*2
Rectifier Terminal
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher. If the result is not as specified, replace the generator holder with rectifier.
Inspect the negative (-) rectifier.
Using an ohmmeter, connect one tester probe to the negative (-) terminal and the other to each rectifier terminal.
Text in Illustration
*1
Negative (-) Terminal
*2
Rectifier Terminal
Reverse the polarity of the tester probes and repeat the step above.
Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher. If the result is not as specified, replace the generator holder with rectifier.
INSPECT GENERATOR ROTOR ASSEMBLY
Check the generator rotor for an open circuit.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Slip ring - Slip ring
20°C (68°F)
1.7 to 2.1 Ω
Text in Illustration
*1
Slip Ring
If the result is not as specified, replace the generator rotor assembly.
Check if the generator rotor is grounded.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Slip ring - Rotor core
Always
10 kΩ or higher
Text in Illustration
*1
Slip Ring
*2
Coil Core
If the result is not as specified, replace the generator rotor assembly.
Inspect the slip rings.
Check that the slip rings are not rough or scored. If the slip lings are rough or scored, replace the generator rotor assembly.
Using a vernier caliper, measure the slip ring diameter.
Standard diameter:
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter:
14.0 mm (0.551 in.)
Text in Illustration
*1
Diameter
If the diameter is less than the minimum, replace the generator rotor assembly.