2013-2015 Land Cruiser Prado · Service Manual Power Source / Network

Charging Failure

Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

INSPECTION PROCEDURE


1. CHECK GENERATOR WITH CLUTCH PULLEY (ON-VEHICLE INSPECTION)
  1. Start the engine and visually check that the generator rotor assembly (fan) in the generator assembly is operating.

    OK:
    The generator rotor assembly (fan) is operating.

    Result:
    Test Result
    Proceed to
    OK
    A
    NG (Generator Assembly (for 80 A Type))
    B
    NG (Generator Assembly (for 100 A Type))
    C



B
REPLACE GENERATOR WITH CLUTCH PULLEY (for 80 A Type) (Click here)

C
REPLACE GENERATOR WITH CLUTCH PULLEY (for 100 A Type) (Click here)
A


2. CHECK GENERATOR WITH CLUTCH PULLEY (UNIT INSPECTION)
  1. Remove the generator assembly.

    1. for 80 A Type: (Click here)
    2. for 100 A Type: (Click here)

  1. Check the installation condition of the generator pulley cap.

    OK:
    The generator pulley cap is not loose or missing.

  1. Check for forming of particles due to friction (for dry type pulley) or grease leaks (for wet type pulley).

    OK:
    There are no large amount of particles (for dry type pulley) or grease leaks (for wet type pulley).

  1. Check the generator with clutch pulley for misalignment (interference with the generator assembly).

    OK:
    The generator with clutch pulley is not misaligned (no interference with the generator assembly).

  1. A288972
    Turn the generator with clutch pulley clockwise and counterclockwise by hand and check for noise.

    OK:
    Noise does not occur when turned in both directions.

  1. Turn the generator with clutch pulley clockwise and counterclockwise by hand and visually check for runout.

    OK:
    The generator with clutch pulley does not have runout.

  1. A288971
    Hold the generator rotor assembly (fan) in the generator assembly with a screwdriver, and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.

OK:
The generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.

Result:
Test Result
Proceed to
OK (Generator Assembly (for 80 A Type))
A
OK (Generator Assembly (for 100 A Type))
B
NG (Generator Assembly (for 80 A Type))
C
NG (Generator Assembly (for 100 A Type))
D



A
REPAIR OR REPLACE GENERATOR ASSEMBLY (for 80 A Type) (Click here)

B
REPAIR OR REPLACE GENERATOR ASSEMBLY (for 100A Type) (Click here)

C
REPLACE GENERATOR WITH CLUTCH PULLEY (for 80 A Type) (Click here)

D
REPLACE GENERATOR WITH CLUTCH PULLEY (for 100 A Type) (Click here)

← ON-VEHICLE INSPECTION (from Aug 2013)Charging Failure (from Aug 2014) →