2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

18 (5) Spill Control Circuit Malfunction

Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

The ECM operates the spill control valve to control the fuel injection volume. The spill control valve is mounted on the injection pump. The spill control valve's solenoid valve opens and closes the injection pressure release port. During fuel injection, the spill control valve is on (closed). The ECM determines the basic fuel injection amount based on the engine speed and accelerator pedal position. Then the ECM uses several other correctional factors to determine the final fuel injection amount. After fuel injection has begun, the ECM ensures the final fuel injection amount by performing the following: 1) by counting the number of NE signals, and 2) by turning the spill control valve from on (closed) to off (open) (injection pressure release port is open).
A119268E04
DTC No.
DTC Detection Condition
Trouble Area
18 (5)
Open or short in the spill control valve circuit at 500 rpm or more.
  1. Open or short in spill control valve circuit
  2. Spill control valve
  3. ECM

WIRING DIAGRAM

A119269E02

INSPECTION PROCEDURE


1. INSPECT SPILL CONTROL VALVE
  1. Inspect the spill control valve (Click here).



NG
REPLACE INJECTION PUMP ASSEMBLY (Click here)
OK


2. CHECK ECM (SPV+ VOLTAGE)

  1. A062416E88
    Disconnect the spill control valve connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C101-12 (SPV+) - C101-14 (E1)
    Ignition switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)

  1. Reconnect the spill control valve connector.



NG
REPLACE ECM (Click here)
OK


3. CHECK ECM (SPV- VOLTAGE)

  1. A110527E06
    Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C101-25 (SPV-) - C101-14 (E1)
    Ignition switch ON
    11 to 14 V

  1. While idling, check the waveform with an oscilloscope connected between the specified terminals of the ECM connector.

    OK:
    Tester Connection
    Condition
    Specified Condition
    C101-25 (SPV-) - C101-14 (E1)
    Idling
    Correct waveform is as shown

    Text in Illustration 
    *a
    Component with harness connected
    (ECM)
    *b
    SPV- signal waveform



NG
Go to step 4
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)

4. CHECK HARNESS AND CONNECTOR (ECM - SPILL CONTROL VALVE)
  1. Disconnect the spill control valve connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    C106-2 - C101-12 (SPV+)
    Always
    Below 1 Ω
    C106-1 - C101-25 (SPV-)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    C106-2 or C101-12 (SPV+) - Body ground
    Always
    10 kΩ or higher
    C106-1 or C101-25 (SPV-) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the spill control valve connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)