2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

Odo/Trip Switch Malfunction

Circuit diagnosis · Vehicles built from Aug 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.

HINT:
The whole light control rheostat should be replaced if the ODO/TRIP switch is malfunctioning.


WIRING DIAGRAM

E202315E02

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (ODO/TRIP CHANGE SW)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Body Electrical / Combination Meter / Data List.

  1. Check the values by referring to the table below.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    ODO/TRIP Change SW
    ODO/TRIP change switch/OFF or ON
    OFF: ODO/TRIP change switch released
    -
    ON: ODO/TRIP change switch pressed

    OK:
    The value displayed on the intelligent tester changes with the actual ODO/TRIP change switch operation.



NG
Go to step 2
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)

2. INSPECT TRIP SWITCH

  1. E204159E01
    Disconnect the G16 trip switch connector.

  1. Inspect the ODO/TRIP switch

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      4 (A/B) - 1 (E)
      ODO/TRIP switch on (pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      1 (A/B) - 4 (E)
      ODO/TRIP switch on (pushed)
      Below 1 Ω
      ODO/TRIP switch off (Not pushed)
      1 MΩ or higher



NG
REPLACE TRIP SWITCH (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
  1. Disconnect the G6 meter connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    G6-11 (RSET) - G16-4 (A/B)
    Always
    Below 1 Ω
    G6-11 (RSET) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    G6-11 (RSET) - G16-1 (A/B)
    Always
    Below 1 Ω
    G6-11 (RSET) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)


← Odo/Trip Switch Malfunction (Aug 2013 – Jul 2014)Operating Light Control Rheostat does not Change Light Brightness (Aug 2013 – Jul 2014) →