Odo/Trip Switch Malfunction
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.
- HINT:
- The whole light control rheostat should be replaced if the ODO/TRIP switch is malfunctioning.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (ODO/TRIP CHANGE SW) |
 |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Check the values by referring to the table below.
Combination Meter
Tester Display
|
Measurement Item/Range
|
Normal Condition
|
Diagnostic Note
|
ODO/TRIP Change SW
|
ODO/TRIP change switch/OFF or ON
|
OFF: ODO/TRIP change switch released
|
-
|
ON: ODO/TRIP change switch pressed
|
- OK:
- The value displayed on the intelligent tester changes with the actual ODO/TRIP change switch operation.
|
NG |
 |
|
|
|
| OK |
|
 |
|
|
| 2. INSPECT TRIP SWITCH |
 |
- Disconnect the G16 trip switch connector.
Inspect the ODO/TRIP switch
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD
Tester Connection
|
Switch Condition
|
Specified Condition
|
4 (A/B) - 1 (E)
|
ODO/TRIP switch on (pushed)
|
Below 1 Ω
|
ODO/TRIP switch off (Not pushed)
|
1 MΩ or higher
|
for RHD
Tester Connection
|
Switch Condition
|
Specified Condition
|
1 (A/B) - 4 (E)
|
ODO/TRIP switch on (pushed)
|
Below 1 Ω
|
ODO/TRIP switch off (Not pushed)
|
1 MΩ or higher
|
|
NG |
 |
|
|
|
| OK |
|
 |
|
| 3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH) |
 |
Disconnect the G6 meter connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD
Tester Connection
|
Condition
|
Specified Condition
|
G6-11 (RSET) - G16-4 (A/B)
|
Always
|
Below 1 Ω
|
G6-11 (RSET) - Body ground
|
Always
|
10 kΩ or higher
|
for RHD
Tester Connection
|
Condition
|
Specified Condition
|
G6-11 (RSET) - G16-1 (A/B)
|
Always
|
Below 1 Ω
|
G6-11 (RSET) - Body ground
|
Always
|
10 kΩ or higher
|
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
| OK |
|
 |
|
|